Specification

Listed by
Underwriters
Laboratories
Optional Accessories (Available at additional cost)
CVM1790SS
GE Cafe
1.7 Cu. Ft. Convection Over-the-Range Microwave Oven
240279
Specification Created 6/11
Filler Panel Kits
JX48BL–Black
JX48WH–White
When replacing a 36" or
42" range hood, this kit fills
in the additional width to
provide a custom built-in
appearance.
For installation between
cabinets only; not for
end-of-cabinet installation.
Each kit contains two
3"-wide filler panels.
Filter Kits
JX81D–Recirculating
Charcoal Filter Kit
To be used when
the Spacemaker
microwave oven
cannot be vented
to the outside.
Duct Equivalent Feet
A. Rectangular-To-round
Transition Adaptor 5 ft.
B. Wall Cap 40 ft.
C. 90° Elbow 10 ft.
D. 45° Elbow 5 ft.
E. 90° Elbow 25 ft.
F. 45° Elbow 5 ft.
G. Roof Cap 24 ft.
Hood Exhaust Duct: Outside ventilation requires a HOOD EXHAUST DUCT. Read the
following carefully.
Exhaust Connection: Thehoodexhausthasbeendesignedtomatewithastandard
3-1/4"x10"rectangularduct.Ifaroundductisrequired,arectangular-to-round
transition adaptor must be used. Do not use less than a 6" diameter duct.
Rear Exhaust:Ifarearorhorizontalexhaustistobeused,careshouldbetakento
alignexhaustwithspacebetweenstuds,orwallshouldbepreparedatthetimeit
is constructed by leaving enough space between the wall studs to accommodate
exhaust.
Maximum Duct Length: For satisfactory air movement, the total duct length of 3-1/4"
x10"rectangularor6"diameterroundductshouldnotexceed140equivalentfeet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS: etc., present additional resistance to
airflow and are equivalent to a section of straight duct which is longer than their
actual physical size. When calculating the total duct length, add the equivalent length
of all transitions and adaptors plus the lengths of all straight duct sections. The chart
belowshowstheapproximatefeetofequivalentlengthofsometypicalducts.