Installation guide
ITI ELECTRICAL REQUIREMENTS (CONT.)
This appliance must be supplied with the proper voltage and frequency and connected to an individual,
properly grounded branch circuit, protected by a circuit breaker or fuse. See the rating plate located on the
oven frame to determine the rating of the product.
Rating plate
is located on
left side trim
Connected
Appliance
Information
right side trim
Use the chart below to determine the minimum recommended dedicated circuit protection:
Recommended
KW Rating KW Rating Circuit Size
240V 208V (Dedicated)
<4.8 KW <4.t KW 20 Amp
4.9 KW-7.2 KW 4.2 KW-6.2 KW 30 Amp
7.3 KW-9.6 KW 6.3 KW-8.3 KW 40 Amp
9.7 KW-12.0 KW 8.4 KW-IO.4 KW 50 Amp
DO NOTshorten the flexible conduit. The conduit strain relief clamp must be securely attached to the
junction box and the flexible conduit must be securely attached to the clamp. If the flexible conduit will not
fit within the clamp, do not install the oven until a clamp of the proper size is obtained.
The 3 power leads supplied with this appliance are suitable for connection to heavier gauge household
wiring. The insulation of these 3 leads is rated for temperatures much higher than the temperature rating of
the household wiring. The current-carrying capacity of the conductor isgoverned by the wire gauge and the
temperature rating of the insulation around the wire.
l_] MAKE ELECTRICAL CONNECTIONS
A WARNING:Sw,tch power off at the service panel and lock the service disconnecting
means to prevent power from being switched on accidentally. When the service disconnecting means
cannot belocked, securely fasten a prominent warning device, such as a tag,
to the service panel.
Place oven on table or platform even with the cutout opening. For a French Door oven, the platform must
support 220 Ibs.(98.8kg). Connect the flexible conduit to the electricaljunction box as shown below*.
Position the conduit in such a manner that it will lie behind the unit in a natural loop when the oven is
installed. You will need to )urchase an appropriate strain relief clamp to complete the connection of the
conduit to thejunction box.
Junction Box
Conduit
PlaceOven on a
Support to Assist in
Connecting Conduit
Strain ReliefClamp
(not included) Must Be
Used at Junction Box
*Ovens come equipped with a 40" long conduit. If a longer conduit isdesired, there may be one available for
your model. To check availability or order parts, call :]_.800.GE.CARES.