Installation guide
4 31-2000354 Rev. 0
Installation Preparation
ELECTRICAL REQUIREMENTS
Single Advantium Built-In Oven Installation:
This product requires a 120-volt, 60 Hz, 15-amp 
circuit and draws 1.8 kilowatts. This product must be 
connected to a supply circuit of the proper voltage and 
frequency. 
•  Wire size must conform to the requirements of the 
National Electrical Code or the prevailing local code for 
this kilowatt rating.
•  The power supply cord and plug should be brought 
to a separate 15 or 20 ampere branch circuit single 
grounded receptacle. The outlet box should be located 
within reach of the 48” power cord.
ELECTRICAL LOCATION
Locate outlet box in the shaded area
6”
9”
Install a recessed electrical outlet 
in the back wall of the opening 
within 6Ǝ of either side and at least 
9Ǝ above the cutout floor.
GROUNDING INSTRUCTIONS 
WARNING
Improper use of the grounding plug can result in a risk of electric shock.
This appliance must be grounded. 
In the event of an electrical short 
circuit, grounding reduces the risk 
of electric shock by providing an 
escape wire for the electric current. 
This appliance is equipped with a 
power cord having a grounding wire with a grounding 
plug. The plug must be plugged into an outlet that is 
properly installed and grounded. 
Consult a qualified electrician or service technician if 
the GROUNDING INSTRUCTIONS are not completely 
understood, or if doubt exists as to whether the 
appliance is properly grounded. 
If the outlet is a standarf 2-prong wall outlet, it is your 
personal responsibility and obligation to have it replaced 
with a properly grounded 3-prong wall outlet. 
Do not under any circumstacnes cut or remove the third 
(ground) prong from the power cord. 
Do not use an extension cord. If the power cord is too 
short, have a qualified electrician or service technician 
install an outlet near the appliance. 
For best operation, plug this appliance into its own 
electrical outlet to prevent flickering of lights, blowing of 
fuse or tripping of circuit breaker.  
Ensure Proper ground 