Specification Sheet
COEFFICIENTS OF UTILIZATION
RC 80% 70% 50% 30% 10% 0%
RW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100
1 108 103 99 95 105 101 97 93 97 93 90 93 90 87 89 87 85 83
2 98 90 82 76 95 88 81 76 84 79 74 81 76 72 78 74 70 68
3 89 78 70 63 87 77 69 63 74 67 61 71 65 60 68 64 59 57
4 82 69 60 53 79 68 59 53 65 58 52 63 57 51 61 55 51 49
5 75 62 53 46 73 61 52 45 58 51 45 56 50 44 55 49 44 42
6 69 56 46 40 67 55 46 40 53 45 39 51 44 39 49 43 39 36
7 64 50 41 35 62 49 41 35 48 40 35 46 40 34 45 39 34 32
8 60 46 37 31 58 45 37 31 44 36 31 43 36 31 41 35 31 29
9 56 42 34 28 54 41 33 28 40 33 28 39 32 28 38 32 28 26
10 52 39 31 25 51 38 31 25 37 30 25 36 30 25 35 29 25 23
BL657A4.IES
Zone Lumens
0-10 88.56
10-20 254.96
20-30 388.49
30-40 471.52
40-50 494.03
50-60 452.69
60-70 356.04
70-80 220.95
80-90 73.24
90-100 0.00
100-110 0.00
110-120 0.00
120-130 0.00
130-140 0.00
140-150 0.00
150-160 0.00
160-170 0.00
170-180 0.00
ZONAL LUMEN SUMMARY
IND108-R061614
Construction:
• Fully recyclable aluminum
For more information and access to all of our resources, including our
design tool visit: www.gelighting.com
Electrical System:
• Class 1, replaceable, high efficiency LED driver rated for 100,000 hours when used within
operating conditions.
• Audible Noise – Per 29CFR 1910 sub part G: <24 dba (1 foot)
• Thermal overload protection shuts down the luminaire when system temperatures exceed
designed operating conditions
• THD: <20%
• Transient Protection: 2.5 kV level 1.2/50microsec repetitive
• Environmental Testing: High Temperature High Humidity: 60°C / 90% (non-condensing)
• Electronic Vibration Testing: Multi Axis, Random Vibration Profile: 2-2000 Hz, 5Gs on electronics
Installation:
• Mounting accessories provided standard
• Integrated PSU enclosure delivers a clean, uninterrupted luminaire below the ceiling grid
• Luminaire Vibration Testing: Luminaire test to 0.5 G, 100,000 cycles per axis, 2 axis
• Can be mounted in continuous runs to provide seamless end-to-end illumination
• Mounting clips are included with fixture, but are field installed based on ceiling grid type used
Product Specifications:
Photometric Data: Lumination BL62, BL64 & BL65 Series
GE Lighting • 1-888-MY-GE-LED (1 - 888 - 69 - 43 - 533) • www.gelighting.com
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. The GE brand, logo and Lumination are trademarks of the General Electric Company.
© 2014 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
NOTE: Floor Cavity Reflectance : 20%
Angle 0° 45° 90°
45 6531 6493 6420
55 6370 6322 6269
65 6164 6084 6032
75 5886 5768 5726
85 5535 5399 5321
CANDLEPOWER SUMMARY
Zone Lumens % of Lamp % of Fixture
0-20 343.52 N.A. 12.30
0-30 732.01 N.A. 26.10
0-40 1203.52 N.A. 43.00
0-60 2150.25 N.A. 76.80
0-80 2727.24 N.A. 97.40
0-90 2800.48 N.A. 100.00
ZONAL LUMEN SUMMARY
Total Luminaire Efficiency = N.A.%
POLAR GRAPH
935
702
468
234
2
1