Installation Guide
SKU Description Code
Number of
mounting
clips required Voltage
Maximum Run Length
Location Rating
64409 GEWI102430BAT
2 120 VAC-277 VAC, 50-60Hz
For both 120 VAC and 277 VAC:
20 xtures (40 feet/ 12 meters)
Dry or Damp
Location
64430 GEWI102440BAT
64431 GEWI102450BAT
94454 GEWI102471BAT
94455 GEWI102440BAT
94456 GEWI102430BAT
64432 GEWI104830BAT
2 120 VAC-277 VAC, 50-60Hz
For both 120 VAC and 277 VAC:
10 xtures (40 feet/ 12 meters)
64433 GEWI104840BAT
64434 GEWI104850BAT
94457 GEWI104871BAT
94458 GEWI104840BAT
94459 GEWI104830BAT
64472 GEWI109630BAT
3 120 VAC-277 VAC, 50-60Hz
For both 120 VAC and 277 VAC:
5 xtures (40 feet/ 12 meters)
64473 GEWI109640BAT
65653 GEWI109650BAT
94460 GEWI109671BAT
94461 GEWI109640BAT
94462 GEWI109640BAT
Specications
Troubleshooting
GE2025-9415
SIGN124-103114
Symptom Solution
All LED xtures are not
illuminated
• Check leader cable connection and/or check circuit breaker.
• Check plug connectors on the LED xtures for improper connections or short circuits.
• Ensure leader cable is securely connected to the female plug connector on the rst LED xture.
Some LED xtures are
not illuminated
• Check plug connectors on the LED xtures for improper connections or short circuits.
• Ensure any jumper cables are securely connected between the male/female plug connectors of the
LED xtures.
(1-888-69-43-533)
GE Lighting • 1-888-MY-GE-LED
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting. The GE brand and logo are trademarks of the General Electric Company.
© 2014 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
• www.gelighting.com
Conforms to the following standards: