Room Air Conditioners Manual
Terminal Connections Remote Thermostat - Class 2 (on some models)
The controls are located under a plastic cover behind the front 
grille.
1. Remove the front grille. See the Front Grille section of Care 
and Cleaning.
2. Remove the screws securing the plastic cover over the wiring 
connections. Set aside screws and plastic cover.
3. To make wiring connections, insert the wires into the bottom 
of the terminals and tighten screws securely.
4. After all desired connections have been made, replace the 
plastic cover and front grille.
The owner is responsible for making all connections and setting 
the appropriate dip switches. 
When connected, the unit will be controlled by a remote 
thermostat.
NOTE: The number 3 dip switch must be in the enabled (UP) 
position to activate the remote thermostat. (See the installation 
instructions supplied with the remote thermostat.)
IMPORTANT:  
The thermostat connections provide 24 V AC only.
If using a digital/electronic wall thermostat, ensure it is 
compatible with 24 VAC signal. See the Installation Instructions 
for the wall thermostat.
NOTICE: 
Damage to a wall thermostat or to the electronics can result 
from improper connections. Special care must be used in 
connecting the wires. No line voltage connections should be 
made to any circuit. Isolate all wires in building from line voltage.
Terminal 
connections 
location 
under front 
grille
Fan Cycle/Continuous - Cool
When this switch is enabled (UP), it allows the indoor fan to cycle 
on/off with the compressor. When this switch is disabled (DOWN), 
 it allows the indoor fan to run continuously. The default setting is 
DOWN (continuous).
Fan Cycle/Continuous - Heat 
When this switch is enabled (UP), it allows the indoor fan to cycle 
on/off with the heater operation. When this switch is disabled 
(DOWN), it allows the indoor fan to run continuously. The default 
setting is UP (cyclic).
Class 2 - Remote Thermostat
When this switch is enabled (UP), it allows the unit to operate with 
a Class 2 Remote Control Wall Thermostat. The unit controls are 
disabled. The default setting is DOWN (disabled).
Fan Cycle/Continuous  -  Cool 
Fan Cycle/Continuous - Heat 
Class 2
9
Red - 24 V AC only
Green - Low Speed Fan
Green - High Speed Fan
Yellow - Compressor
  White - Heater
Common - Ground
  No Function  
 (reserved for furture use) 
  No Function  
 (reserved for furture use) 