Room Air Conditioners Manual
Installation Instructions
PREPARE OPENING IN WALL
Make certain a wall receptacle is available close  
to the hole location or make arrangements to install 
a receptacle.
The cord length for the 115-volt models is 72s 
to the right and 47s to the left. 
For the 230/208-volt models the cord length is 65s 
to the right and 39sto the left.
1
,167$//,1*7+528*+7+(:$//
Read these instructions completely and carefully.
 SUPPORT REQUIREMENTS FOR AIR 
&21',7,21(5
The air conditioner wall case may be installed  
with 1/4s min. extension out from the inside wall 
or with 1/4s min. extension out from the outside wall.
The finished sides of the opening should be structural 
wall members.
/LQWHO² Use a lintel in brick veneer and brick  
and block types of wall to support the bricks  
or blocks above the opening. Do not allow the wall 
case to be used in lieu of a lintel.
)ODVKLQJ² Install flashing (drip rail) as shown  
to prevent water from dripping inside the wall  
and down the outside of the building.
2
Trim 
molding 
(if desired)
Plaster line
Caulking 
(above 
and 
below the 
flashing)
1/4s min. extension 
inside the wall from 
the trim molding
Room side
Flashing 
(drip rail)
Brick veneer
Caulking 
(on all 4 sides  
on the outside  
and inside  
of the case)
Lintel angle 
(if required)
 SUPPORT REQUIREMENTS FOR AIR 
&21',7,21(5
Mortar between the case and the brick wall around  
the case may be undercut at about 45° for  
improved caulking.
3
Caulking
Top of case
Inside
Outside
Undercut 
mortar
 MINIMUM 
 ),1,6+(' 
 OPENING 
 ',0(16,216 &$6(',0(16,216
 +HLJKW :LGWK +HLJKW :LGWK 'HSWK
   
 15
3
ø4s 26
1
ø8s 15
5
ø8s 26
1
ø16s
16s
* Dimensions may need 
to be increased to fit 
unique situations in the 
field if using case angles.
16