Brochure

7 GE
Gas Turbines
GE10-2 Gas Turbines
Mechanical Drive Package Arrangement
The GE10-2 package is designed for optimum performance in pipeline, re-injection and other oil and
gas field applications (on- and off-shore), as a pump drive, and also for power generation applications.
The base configuration consists of a complete unit configured for outdoor installation and has
been developed for hazardous area installation in accordance with API standards.
The enclosure guarantees a sound pressure level below 85 dBA at 1 m.
The main skid incorporates the gas turbine, electric starting system, fuel system, and gas
detection and firefighting systems (CO
2
).
The lube oil tank is integral with the gas turbine base plate. The main lube oil pump is mechanical,
and is driven by the auxiliary gearbox. The auxiliary oil pump is an AC electric motor-driven
pump, and a DC electric motor-driven pump is provided for emergency backup. All control
devices are located in a separate control room.
The air filtration system consists of a “self cleaning type”
filter house, an inlet duct and a silencer.
The combustion chamber and valve system can
accommodate different types of gas/liquid fuel
compositions and NOx emission requirements.
An engine exchange maintenance option is
available to reduce maintenance cost and time.
The package is mechanically tested prior to delivery.
AVAILABLE OPTIONS
- Dual Fuel DLN version (liquid + gas fuel)
- 80 dBA sound pressure level package
- Indoor version
-H
2
O type fire fighting system
- Static air filter system
-H
2
O oil cooler system
- Gas expansion turbine starting system
GE10-2 (ISO Conditions Standard Combustor)
Electrical Output (kW) 11982
Electrical Efficiency (%) 33.3
Exhaust Flow (kg/sec) 47.0
Exhaust Temperature (°C) 480
-30 -20 -10 0 10 15 20 30 40 50
18000
16000
14000
12000
10000
8000
6000
4000
12500
12000
11500
11000
10500
10000
Ambient Temperature (C)
Output (kW)
GE10-2 Output & Heat Rate
Shaft Power Output
Engine Heat Rate
Heat Rate (kJ/kWhr)
0 255075100
200
175
150
125
100
75
LPT = 100%
LPT = 85%
LPT = 70%
LPT = 50%
Shaft Power (percentage of ISO Base Load)
Heat Rate (percentage of ISO Heat Rate)