Brochure
5 GE
Gas Turbines
GE10-1 Gas Turbines
GENERAL SPECIFICATIONS
Axial Compressor
- 11-Stage Axial Flow
- 15.5:1 Pressure Ratio
Combustion Chamber
- Single Can Combustor
- Pollution prevention:
- DLN Gas Fuel at 25 ppmvd NOx
- DLN Gas Fuel at 15 ppmvd NOx
- DLN Dual Fuel Gas Fuel at 25 ppmvd NOx
- DLN Dual Fuel Liquid Fuel at 85 ppmvd NOx
Turbine
- 3-Stage HP Turbine 11000 rpm
AVAILABLE OPTIONS
- Dual Fuel DLN version (liquid + gas fuel)
- 6.0kV electric generator
- 80 dBA sound pressure level package
- Indoor version
-H
2
O oil cooler system
- Standard exhaust duct (12 m)
- Lubrication stand-by pump
- Control cabinet located alongside the unit
- Additional pre-engineered BN1701 for complete
vibration monitoring
Turbine
The single-shaft version is optimized for power generation applications.
The turbine consists of three reaction stages. In the first two stages the hot gas parts are cooled
by air extracted from the axial compressor. The second and third stages have interlocked shrouds to
limit tip leakage and blade vibration.
Power Generation Package Arrangement
The GE10-1 package is designed specifically for power generation applications in both Simple Cycle
and CHP Cycle modes.
The single lift architecture (main skid dimension 12.5 m x 2.5 m) minimizes site installation and
commissioning lead time (1.5 months). The integrated control cab eliminates the need for control
room civil works and related site wiring. An engine exchange maintenance option is available (5
days downtime) to reduce maintenance cost and time.
Each package is performance tested before shipping to ensure product reliability and quality.
The base configuration consists of a complete unit configured for outdoor installation.
The enclosure guarantees a sound pressure level below 85 dBA at 1 m.
The main skid incorporates the Gas Turbine, Electric
Generator (11 kV, 4-poles, open air) which also acts
as a starting motor, and the Gearbox (Epicyclical).
The Combustion chamber and valve system is able
to accommodate different types of gas/liquid fuel
compositions and NOx emission requirements.
GE10-1 (ISO Conditions Standard Combustor)
Electrical Output (kW) 11250
Electrical Efficiency (%) 31.4
Exhaust Flow (kg/sec) 47.5
Exhaust Temperature (°C) 482