Brochure

29 GE
Gas Turbines
Mechanical Drive
(ISO conditions - natural gas - shaft output)
ISO RATED HEAT RATE EFFIC. PRESSURE EXHAUST TURBINE EXHAUST
POWER RATIO FLOW SPEED TEMPERATURE
kW shp kJ/kWh btu/shp-h % kg/sec Ibs/sec RPM °C °F
GE10-2 11,982 16,068 10,822 7,651 33.3 15.5 46.7 103.0 7,900 480 896
PGT16 14,240 19,096 9,924 7,016 36.3 20.2 47.3 104.3 7,900 491 916
PGT20 18,121 24,300 9,867 6,975 36.5 15.7 62.6 137.9 6,500 475 887
PGT25 23,266 31,200 9,548 6,750 37.7 17.9 68.9 151.9 6,500 525 976
PGT25+ 31,372 42,070 8,751 6,187 41.1 21.5 84.3 185.8 6,100 500 932
PGT25+G4 34,302 46,000 8,719 6,162 41.2 23.8 89.6 197.7 6,100 510 950
LM6000* 43,854 58,809 8,468 5,985 43.0 28.0 125.0 275.0 3,600 455 851
LMS100* 100,200 8,160 44.1 40.0 206.9 456.0 3,600 417 782
MS5002C 28,340 38,005 12,467 8,814 28.8 8.8 124.3 274.1 4,670 517 963
MS5002E* 32,000 42,912 10,000 7,070 36.0 17.0 102.0 225.0 5,714 511 952
MS5002D 32,580 43,690 12,235 8,650 29.4 10.8 141.4 311.7 4,670 509 948
MS6001B 43,530 58,380 10,820 7,650 33.3 12.2 140.0 309.0 5,111 544 1,011
MS7001EA 86,226 115,630 10,920 7,720 33.0 12.6 296.0 652.5 3,600 535 995
MS9001E 130,140 174,520 10,397 7,350 34.6 12.7 410.0 901.0 3,000 540 1,004
(*) DLE Combustion