Installation Guide

ALB006-012114
Troubleshooting
Symptom Solution
Luminaire will not turn on. • Check that the color of the supply side wires match the color of the wires they are connected to.
• Check that all wire connectors are properly connected.
• Verify that your input voltage is within specs.
• If you are using any additional controls i.e. wireless controls/motion sensors, please also verify that
those are working properly and that the unit is setup to interface with the controllers.
Mounting insert slides
from side to side.
• Check that the mounting insert is properly tightened using the adjustment screws provided.
Endplate of Pendant Mount Kit
does not snap in place.
• Check that the top plate is properly slotted in main bracket.
• Check that endplate tabs are properly aligned in pendant mount bracket assembly.
• Check that endplate is pushed rmly into place.
1
3
2
4
Attach pendant mount bracket assembly to four
mounting inserts on the xture with (8) 10-32 x 3/8”
Philips pan head screws.
Slide top plate into main bracket. Align top tabs of end
plate with slots in main bracket and push endplate into
place.
Attach top plate to 3/4” conduit and pass AC input wires
through conduit, top plate, and locking nut (if used).
Connect the AC input wires to the xture wires coming
from the strain relief in the main bracket assembly
bottom plate.
Fasten endplate to bracket with a 8-32 x 1/4” Philips pan
head screw. Fasten endplate to mounting hub with a
6-32 x 1/2” hex head screw.
Pendant Mount Kit
OPTION B
AC line
Align tabs
Fasten screws
NOTE: Pendant Mount Kit cannot be used with the 6-module xture.