Troubleshooting
Symptom Solution
Luminaire will not turn on. • Check that the color of the supply side wires match the color of the wires they are connected to.
• Check that all wire connectors are properly connected.
• Verify that your input voltage is within specs.
• If you are using any additional controls i.e. wireless controls/motion sensors, please also verify that
those are working properly and that the unit is setup to interface with the controllers.
Mounting insert slides
from side to side.
• Check that the mounting insert is properly tightened using the adjustment screws provided.
Endplate of Pendant Mount Kit
does not snap in place.
• Check that the top plate is properly slotted in main bracket.
• Check that endplate tabs are properly aligned in pendant mount bracket assembly.
• Check that endplate is pushed rmly into place.
1
3
2
4
Attach pendant mount bracket assembly to four
mounting inserts on the xture with (8) 10-32 x 3/8”
Philips pan head screws.
Slide top plate into main bracket. Align top tabs of end
plate with slots in main bracket and push endplate into
place.
Attach top plate to 3/4” conduit and pass AC input wires
through conduit, top plate, and locking nut (if used).
Connect the AC input wires to the xture wires coming
from the strain relief in the main bracket assembly
bottom plate.
Fasten endplate to bracket with a 8-32 x 1/4” Philips pan
head screw. Fasten endplate to mounting hub with a
6-32 x 1/2” hex head screw.
Pendant Mount Kit
OPTION B
AC line
Align tabs
Fasten screws
NOTE: Pendant Mount Kit cannot be used with the 6-module xture.
GE Lighting • 1-888-MY-GE-LED (1-888-69-43-533) • www.gelighting.com
The GE brand, logo, and Albeo are trademarks of the General Electric Company.
© 2013 GE. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
Conforms to the following standards:
UL 1598 Suitable for Damp Locations