Installation Guide
ALB007-020514
Troubleshooting
Symptom Solution
Luminaire will not turn on. • Check that the color of the supply side wires match the color of the wires they are connected to.
• Check that all wire connectors are properly connected.
• Verify that your input voltage is within specs.
Mounting insert slides
from side to side.
• Check that the mounting insert is properly tightened using the adjustment screws provided.
GE Lighting • 1-888-MY-GE-LED (1-888-69-43-533) • www.gelighting.com
The GE brand, logo, and Albeo are trademarks of the General Electric Company.
© 2014 GE. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
4
DALI 1-10V
3
Connect the AC line to the power terminal block as follows:
Brown to L1, Blue to N, and Green/yellow to ground.
Reattach endcap if there is no dimming line.
Optional DALI and 1-10V Dimming: Follow wiring
diagram below. Reattach endcap.
For Step 4: Follow diagram A for DALI or diagram B for 1-10V. The LED luminaire is pre-programmed for either DALI or
1-10V dimming at the factory. Run wires from controller through a different knockout than the AC input wire. At output
side of LED driver, make appropriate connections to the dimming terminal block. Follow lighting controller installation
instructions.
A
DALI Controller
B
1-10V Dimmer
Optional 1-10V Volt Dimming or DALI Lighting Controller
Brown
To AC Main
Blue
Green/Yellow
Violet
Grey
Line
Neutral
Ground
1-10V(+)
1-10V(-)
LED Driver
To 1-10V
Dimmer
Brown
To AC Main
Blue
Green/Yellow
Violet/White
Violet
Line
Neutral
Ground
DALI
DALI
LED Driver
To DALI
Controller