GE Appliances Room Air Conditioners Owner’s Manual & Installation Instructions AG_14 –14,000 BTU models AG_18 –18,000 BTU models AG_24 –24,000 BTU models www.geappliances.com 3828A30036P Pub. No.
Safety Instructions Safety Information GE & You, A Service Partnership. Safety Precautions . . . . . . . . . . . .3 How to Connect Electricity . . . . . .3 Use of Extension Cords . . . . . . . . .4 Use of Adapter Plugs . . . . . . . . . .4 IMPORTANT! Fill out the Consumer Product Registration Card. Two easy ways to register your appliance! ■ Through the internet at www.geappliances.
Safety Instructions IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury. SAFETY PRECAUTIONS ■ This air conditioner must be properly installed in accordance with the Installation Instructions before it is used. ■ Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
WARNING! USE OF EXTENSION CORDS – 115-Volt models only Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord. However, if you must use an extension cord, it is absolutely necessary that it be a UL-listed, 14 gauge, 3-wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes (minimum) and 125 volts.
Safety Instructions About the controls on the air conditioner. Features and appearance will vary. OFF OFF HIGH COOL LOW FAN MED COOL HI FAN HI COOL LOW FAN LOW COOL Operating Instructions HIGH FAN LOW COOL MODE CONTROLS Your model will have one of the above type controls. 5 6 4 4 7 5 3 3 2 8 3 2 9 1 5 7 1 1 8 Installation Instructions 2 4 6 6 10 TEMP CONTROLS Your model will have one of the above type controls.
Additional controls and important information. Energy Saver (on some models) The energy saver switch controls the fan. ON —The fan and compressor cycle on and off together. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied. Operating Instructions Safety Instructions About the controls on the air conditioner. OFF — The fan runs all the time, while the compressor cycles on and off.
Grille and Case Turn the air conditioner off and remove the plug from the wall outlet before cleaning. To clean, use water and a mild detergent. Do not use bleach or abrasives. Safety Instructions Care and cleaning of the air conditioner. Outdoor Coils Operating Instructions The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through your GE service outlet.
Read these instructions completely and carefully. Before You Begin NOTE TO INSTALLER: Leave these instructions with the air conditioner after installation is completed. CAUTION: Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. NOTE TO CONSUMER: Keep this Owner’s Manual and Installation Instructions for future use. Operating Instructions Safety Instructions Preparing to install the air conditioner.
Safety Instructions Window Installation Instructions Parts Included Top mounting rail Window sash seal Left accordion panel Foam top window gasket Operating Instructions Top mounting rail seal strip Installation Instructions Frame guide (2) Right accordion panel Sill bracket (2) Support bracket (2) Window locking bracket Type B (7) Type C (5) Type D (2) Carriage Bolt (2) Troubleshooting Tips Type A (14) Lock Nut (4) Customer Service 9
Safety Instructions Window Installation Instructions Read completely, then follow step-by-step. 1 Window Requirements ■ These instructions are for a standard doublehung window. You will need to modify them for other types of windows. ■ The air conditioner can be installed without the 18″ min. ■ All supporting parts must be secured to firm 29″ to 41″ (With accordion panels) wood, masonry or metal. ■ The electrical outlet must be within reach of the power cord. 261⁄4″ min.
Safety Instructions 3 Remove the Air Conditioner From the Case A Remove the 2 shipping screws from the back of the case. B Remove the 2 screws on each side of the case. Keep these for later use. Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case. C Remove the backing from the top mounting rail seal strip and attach the seal to the bottom of the top mounting rail.
Safety Instructions Window Installation Instructions 5 Prepare the Window A Loosely attach the sill brackets to the support brackets using the 2 carriage bolts and 2 lock nuts. B Support bracket Open the window and mark the centerline of the window stool. Measure and mark 11″ to the left and right of the centerline.
Attach the window locking bracket with a type C screw. Cut the foam top window gasket to the window width. C Stuff the foam between the glass and the window to prevent air and insects from getting into the room. C Attach the front grille to the case by inserting the tabs on the grille into the slots on the front of the case. Push the grille in until it snaps into place. Install the Air Conditioner in the Case A Slide the air conditioner into the case.
Safety Instructions Operating Instructions Troubleshooting Tips Save time and money! Review the chart below first and you may not need to call for service. Problem Possible Causes What To Do Air conditioner does not start The air conditioner is unplugged. • Make sure the air conditioner plug is pushed completely into the outlet. The fuse is blown/circuit breaker is tripped. • Check the house fuse/circuit breaker box and replace the fuse or reset the breaker. Power failure.
Safety Instructions Notes.
Customer Service Troubleshooting Tips Installation Instructions Operating Instructions Safety Instructions Notes.
GE Service Protection Plus™ GE, a name recognized worldwide for quality and dependability, offers you Service Protection Plus ™—comprehensive protection on all your appliances— No Matter What Brand! Benefits Include: • Backed by GE • All brands covered • Unlimited service calls • All parts and labor costs included • No out-of-pocket expenses • No hidden deductibles • One 800 number to call We’ll Cover Any Appliance. Anywhere. Anytime.
Consumer Product Ownership Registration Dear Customer: Thank you for purchasing our product and thank you for placing your confidence in us. We are proud to have you as a customer! Follow these three steps to protect your new appliance investment: 1 2 3 Complete and mail your Consumer Product Ownership Registration today. Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification. After mailing the registration below, store this document in a safe place.
Safety Instructions Air Conditioner Warranty All warranty service provided by our Factory Service Centers, or an authorized Customer Care® technician. For service, call 800-GE-CARES. GE Will Replace: One Year From the date of the original purchase Any part of the air conditioner which fails due to a defect in materials or workmanship. During this full one-year warranty, GE will also provide, free of charge, all labor and in-home service to replace the defective part.
Safety Instructions Service Telephone Numbers. GE Answer Center ® 800.626.2000 The GE Answer Center® is open 24 hours a day, 7 days a week. In-Home Repair Service 800-GE-CARES (800-432-2737) Operating Instructions Expert GE repair service is only a phone call away. Special Needs Service 800.626.2000 800-TDD-GEAC (800-833-4322) Installation Instructions GE offers, free of charge, a brochure to assist in planning a barrier-free kitchen for persons with limited mobility.