Installation Instructions / Warranty

55
Model Number Fan Motor- 230 Volts Fan Motor- 208 Volts Model Number Fan Motor - 265 Volts
Maximum Connected Load For
Premium Series (5200)
The maximum connected load of a Zoneline unit occurs
when the unit is in resistance heating operation. To
determine the maximum amperage draw or wattage
consumption of the unit: First, find the chassis model
number in TABLE A and read the amperage or wattage of
the unit in the appropriate column; Second, find the power
connection kit to be used in TABLE B and read the
amperage or wattage of the heater in the appropriate
column.
The sum of the fan motor requirements TABLE C and the
heater requirements TABLE D equal the Maximum
Connected Load of the unit.
Table C
Heating Operation - Indoor Fan Motor Electrical Data
Watts Amps Watts Amps Watts Amps
AZ52H07DAB/DAD* 25 0.1 20 0.1 AZ52H07EAB/EAD* 30 0.1
AZ52H09DAB/DAD* 25 0.1 20 0.1 AZ52H09EAB/EAD* 30 0.1
AZ52H12DAB/DAD* 25 0.1 20 0.1 AZ52H12EAB/EAD* 30 0.1
AZ52H15DAB/DAD* 45 0.2 40 0.2 AZ52H15EAB/EAD* 50 0.2
Outdoor Fan Motor Electrical Data
Two Fan Motor Models
For Information Only. Do Not Include In Maximum Connected Load Calculations.
Model Number Fan Motor- 230 Volts Fan Motor- 208 Volts Model Number Fan Motor - 265 Volts
Watts Amps Watts Amps Watts Amps
AZ52H07DAB/DAD 65 0.3 60 0.3 AZ52H07EAB/EAD 75 0.3
AZ52H09DAB/DAD 65 0.3 60 0.3 AZ52H09EAB/EAD 75 0.3
AZ52H12DAB/DAD 90 0.4 80 0.4 AZ52H12EAB/EAD 100 0.4
AZ52H15DAB/DAD 135 0.6 125 0.6 AZ52H15EAB/EAD 135 0.5
Table D
Heating Operation - Resistance Heater Electrical Data
Heater - 230 Volts Heater - 208 Volts Heater - 265 Volts
Power
Connection
Kit
Power
Connection
Kit
Watts Amps Watts Amps Watts Amps
RAK3152 2550 11.1 2085 10.0 RAK5152 1700 6.4
RAK3202 3450 15.0 2820 13.6 RAK5172 3000 11.3
RAK3302 5000 21.7 4090 19.7 RAK5202 3700 14.0
RAK5302 5000 18.9
* These models have 2 fan
motors. Information shown is
for the indoor fan motor only.