Installation Instructions / Warranty

52
2200 Series Units Dry Air 25
230/208V Models AZ22E07D AZ22E09D AZ22E12D AZ22E15D AZ22E07D*P AZ22E09D*P AZ22E12D*P
Capacity
Cooling BTUH 7,100/6,900 9,000/8,800 11,700/11,500 14,600/14,300 6,800/6,600 8,600/8,400 11,200/11,000
EER (BTU/Watt) 11.6/11.6 11.3/11.3 10.7/10.7 9.6/9.6 11.1/11.1 10.8/10.8 10.2/10.2
Dehumidification Pts/Hr 1.7 2.7 3.6 4.5 2.2 3.4 4.5
Features
CFM, Indoor Fan High 240 260 270 310 230 230 240
CFM, Indoor Fan Low 210 230 240 280 200 200 210
Vent CFM 40/35 65/60 70/65 70/65 40/35 65/60 70/65
Power/Ratings
Power Factor 95 96 97 94 95 96 97
Sensible Heat Ratio @ 230 Volts 75% 68% 67% 67% 66% 58% 57%
Watts 610/595 795/780 1095/1075 1520/1490 610/595 795/780 1095/1075
Amperes, F.L. 2.8/3.0 3.6/3.9 4.9/5.3 7.0/7.5 2.8/3.0 3.6/3.9 4.9/5.3
Amperes, L.R. 19.0 21.0 33.0 38.0 19.0 21.0 33.0
Weight (Ship/Net)** 119/103 122/105 131/114 138/122 124/108 127/110 136/119
265V Models AZ22E07E AZ22E09E AZ22E12E AZ22E15E AZ22E07E*P AZ22E09E*P AZ22E12E*P
Capacity
Cooling BTUH 7,100 9,000 11,700 14,600 6,800 8,600 11,200
EER (BTU/Watt) 11.6 11.3 10.7 9.6 11.1 10.8 10.2
Dehumidification Pts/Hr 1.7 2.7 3.6 4.5 2.2 3.4 4.5
Features
CFM, Indoor Fan High 240 260 270 310 230 230 240
CFM, Indoor Fan Low 210 230 240 280 200 200 210
Vent CFM 40 65 70 70 40 65 70
Power/Ratings
Power Factor 90 94 94 96 96 94 94
Sensible Heat Ratio @ 265 Volts 75% 68% 67% 67% 66% 58% 57%
Watts 610 795 1095 1520 610 795 1095
Amperes, F.L. 2.4 3.2 4.4 6.0 2.4 3.2 4.4
Amperes, L.R. 16.0 18.0 24.0 31.0 16.0 18.0 24.0
Weight (Ship/Net)** 119/103 122/105 131/114 138/122 124/108 127/110 136/119
*For Dry Air 25 model number, designate respective heater number using chart above, followed by the letter “P”.
** ICR adds 3 pounds to unit weight
Deluxe Series - Cooling & Electric Heat Dry Air 25
Zoneline
®
Chassis Nomenclature
The Zoneline chassis is identified by a model number defining the type of unit, cooling capacity, electrical information and optional features
included on the unit. When specifying or ordering the Zoneline chassis the use of this nomenclature will assure receiving the correct unit.
Example
A Z 5 2 H 1 2 D A D
Zoneline
®
Packaged Terminal Chassis
Chassis Series
22 - Deluxe Line Cool/Electric Heat
32 - Deluxe Line Heat Pump
52 - Premium Line Heat Pump
Unit Type
E - Cooling with Electric Resistance Heat
H - Heat Pump with Electric Resistance Heat
Special Features
B - Base Unit
C - Corrosion Treated
D - Internal Condensate Removal
(ICR) System (Heat Pump Models Only)
P - Dry Air 25
5200 Universal Power Connection
(see Premium Series Models - see page 53)
2200, Dry Air 25 & 3200 Numeric Designator
of Heater Size
(see Deluxe Series Models - see Page 52)
Voltage/Frequency
D - 230/208 Volt 60 Hz E - 265 Volt 60 Hz
Nominal Cooling Capacity
07 - 7,000 BTUH Cooling 12 - 12,000 BTUH Cooling
09 - 9,000 BTUH Cooling 15 - 15,000 BTUH Cooling
Deluxe Line: 2200,
Dry Air 25 & 3200 Series -
Models are manufactured with fixed
heater wattages with the appropriate
power cord attached (all 265 volt models
are permanently connected). 5.0 KW
heaters are not available on 7,000 BTUH
models.
Heater Table
Heater Heater Minimum
Voltage Amps Designator Watts KWH Ampacity BTUH
230/208 11.1/10.0 2 2550/2090 2.55/2.09 15 8,600/7,100
230/208 15.0/13.6 3 3450/2820 3.45/2.82 20 11,700/9,600
230/208 21.7/19.7 5 5000/4090 5.00/4.09 30 17,000/13,900
265 7.5 2 2000 2.0 15 6,800
265 11.3 3 3000 3.0 15 10,200
265 15.1 4 4000 4.0 20 13,600
265 18.9 5 5000 5.0 30 17,000