Specification Sheet
AZ45E09EAC
GE
Zoneline
®
 Cooling and Electric Heat Unit with Corrosion Protection, 265 Volt
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES) 
For more information, please visit our website at zoneline.com or call 888.231.2548.
Specification Revised 7/16
265 VOLT SUB-BASE CONNECTED UNITS
SUB-BASE
POWER 
CONNECTION 
KIT
ELECTRIC  
HEATE R 
WATTS
ELECTRIC  
HEAT AMPS
MIN. CIRCUIT 
PROTECTION 
(AMPS)
RAK204E15 RAK515D 2,460 9.1 15
RAK204E20 RAK520D 3,470 12.8 20
RAK204E30 RAK530D 4,870 18.1 30
MAXIMUM CORD EXTENSION
SIDE
VIEW
Inside
Room
 Cabinet
Outside
58
21
Grille
7-1/8
RAB71A = 16
RAB77A = 16-1/4
RAB71A = 20-7/8
RAB77A = 21
Room Air/Installation QSart
A
C
B
Zoneline RAC Wall Installation
WALL CASE DIMENSIONS
RAB71B WALL SLEEVE 
Heavy-gauge galvanized steel, 
with insulation.  
A – 42", B – 13-3/4", C – 16" 
Also available in 16" and 24" 
depths
RAB77B WALL SLEEVE 
 Molded SMC fiberglass-
reinforced polyester compound.  
A – 42-1/8", B– 13-7/8", 
C – 16-1/4"
WALL OPENING 
DIMENSIONS 
Add 1/4" to A and C dimensions  
for all cut-outs. 
RAB71B 16-1/4" Min. H x 
42-1/4" Min. W 
RAB77B 16-1/2" Min. H x 
42-3/8" Min. W
ELECTRICAL WIRING
All wiring, including installation of receptacle, must  
be made in accordance with local electrical codes  
and   regulations.
NOTE: Aluminum wiring may pose special problems – consult a 
qualified electrician.
GRILLE OPTIONS 
Stamped Aluminum Grille – RAG60 
Exterior Architectural Louvers Durable Polycarbonate: 
RAG61 (Beige)  RAG63 (Dark Brown) 
RAG62 (Maple) 
Extruded Aluminum Architectural Grille – RAG67
RETROFIT KITS: 
RAK40 – Deflector Kit to adapt chassis for use with  
existing (non-GE) exterior louvered grilles.
DUCTED APPLICATIONS 
AZ45 and AZ65 Series can be used with ductwork to heat or cool more 
than one room. RAK6053 Duct Adaptor is applied to the top of case 
over the air discharge. RAK601B Duct Extension is applied to right or 
left of adaptor. Locally fabricated ductwork may be added to extend to 
maximum recommended straight distance of 15 feet in one direction.
ELECTRICAL CONNECTION 
265 volt units are provided with a junction box and require direct 
connection or permanent direction per NEC. See Architects and 
Engineers Design Data Manual for electrical connection information 
including use of sub-base for direct connected units. Installation must 
 comply with local electrical codes and regulations. 
Power connection kits are required on all Zoneline chassis.