and GE Bottom-Freezer Installation Instructions
44  49-1000585 Rev. 1
3ODFHWKHFRPSUHVVLRQQXWDQGIHUUXOHVOHHYH
for copper tubing onto the end of the tubing and 
connect it to the shutoff valve. 
Make sure the tubing is fully inserted into the valve. 
Tighten the compression nut securely.
)RUSODVWLFWXELQJIURPD6PDUW&RQQHFW
™
Refrigerator Tubing kit, insert the molded end 
of the tubing into the shutoff valve and tighten 
compression nut until it is hand tight, then tighten 
one additional turn with a wrench. Over tightening 
may cause leaks.
  NOTE: Commonwealth of Massachusetts 
Plumbing Codes 248CMR shall be adhered to. 
Saddle valves are illegal and use is not permitted 
in Massachusetts. Consult with your licensed 
plumber.
 CONNECT THE TUBING TO THE 
VALVE
7
Turn the main water supply on and flush out the 
tubing until the water is clear.
Shut the water off at the water valve after about 
RQHTXDUWOLWHURUPLQXWHVRIZDWHUKDVEHHQ
flushed through the tubing.
 FLUSH OUT THE TUBING
8
Saddle-Type 
Shutoff Valve
Compression Nut
Packing Nut
Outlet Valve
)HUUXOHVOHHYH
SmartConnect
™
Tubing
 )DVWHQWKHVKXWRIIYDOYHWRWKHFROGZDWHUSLSH
with the pipe clamp.
  NOTE: Commonwealth of Massachusetts 
Plumbing Codes 248CMR shall be adhered to. 
Saddle valves are illegal and use is not permitted 
in Massachusetts. Consult with your licensed 
plumber.
 FASTEN THE SHUTOFF VALVE
4
  Tighten the clamp screws until the sealing washer 
begins to swell. 
  NOTE:'RQRWRYHUWLJKWHQRU\RXPD\FUXVK 
the tubing.
 TIGHTEN THE PIPE CLAMP
5
Pipe Clamp
Vertical Cold 
Water Pipe
Saddle-Type 
Shutoff Valve
Washer
,QOHW(QG
Pipe Clamp
Clamp 
Screw
  Route the tubing between the cold water line and 
the refrigerator.
  Route the tubing through a hole drilled in the wall 
or floor (behind the refrigerator or adjacent base 
FDELQHWDVFORVHWRWKHZDOODVSRVVLEOH
 ROUTE THE TUBING
6
To complete the installation of the refrigerator, go 
EDFNWR6WHSLQ,QVWDOOLQJWKH5HIULJHUDWRU
Installation Instructions
INSTALLING THE WATER LINE (Cont.)
INSTALLATION INSTRUCTIONS