Use and Care Manual

16
Installation Instructions
INSTALLATION—VENTED TO THE OUTSIDE
CONNECT DUCTWORK
Remove shipping tape from the damper.
Install ductwork, making connections
in the direction of airflow as illustrated.
Push duct over the exhaust outlet and damper.
Secure joints in ductwork with sheet metal screws.
Wrap all duct joints and the flange connections
with aluminized duct tape for an airtight seal.
CAUTION:Do not use sheet metal
screws at the hood flange connection. Doing so will
prevent proper damper operation. Seal connection
with tape only.
5
Duct tape
over seam
and screw
Screw
Airflow
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING: If house wiring is not 2-wire
with a ground wire, a ground must be provided
by the installer. When house wiring is aluminum,
be sure to use U.L. approved anti-oxidant compound
and aluminum-to-copper connectors.
Remove the 6 screws on the junction box cover
and the knockout on the top left side.
Secure the house wiring to the junction box with
a strain relief (not provided).
Connect the white lead to the branch circuit white lead.
Connect the black lead to the branch circuit black lead.
Connect the green/yellow lead to the branch
circuit green lead or bare ground lead.
Secure all the connections with wire nuts on each
electrical connector.
Push the wires into the junction box and replace
the cover. Be sure the wires are not pinched.
Secure the junction box cover with the 6 original
screws.
6
Junction
box cover
Knockout