Installation Guide
2 C
 CUTOUT FOR DOUBLE OVENS 
(2 THERMAL OVENS)
NOTE: If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick, shim 
both sides equally to establish the cutout width.
Dim. Description 27” Double Oven 30” Double Oven 
with Pedestal
30” Double Oven 
without Pedestal
A Cabinet Width 27” (68.6 cm) 30” (76.2 cm) 30” (76.2 cm)
B Cutout Width 25” (63.5 cm) min.  
25
1
⁄4” (64.1 cm) max.
28
1
⁄2” (72.4 cm) min.  
28
5
⁄8” (72.7 cm) max.
28
1
⁄2” (72.4 cm) min.  
28
5
⁄8” (72.7 cm) max.
C Cutout Height 49
11
⁄16” (126.2 cm) min.  
50
1
⁄8” (127.3 cm) max.
51
13
⁄16” (131.6 cm) min.  
51
15
⁄16” (131.9 cm) max.
50 ¼” (127.64cm) 
Recommended
D Overlap of Oven Over 
Side Edges of Cutout
1” (2.5 cm)
11
⁄16” (1.75 cm)
11
⁄16” (1.75 cm)
E Clearance to 
Adjacent Corners, 
Drawers, Walls, etc., 
When Door Is Open
20” (50.8 cm) min. 21” (53.3 cm) min. 21” (53.3 cm) min.
F Overlap of Oven Top 
of Cutout
1” (2.5 cm) min. 1” (2.5 cm) min. 1” (2.5 cm) min.
G Overlap of Oven 
Bottom of Cutout
1” (2.5 cm) min. 1
1
⁄4” (3.2 cm) 1
1
⁄4” (3.2 cm)
H Junction Box 
Location 
8
3
⁄4” (22.2 cm) max. 
right side only
9
1
⁄2” (24.1 cm) max. 
right side only
9
1
⁄2” (24.1 cm) max. 
right side only
J Height to Bottom of 
Junction Box
44” (111.8 cm) 47” (119.4 cm) 47” (119.4 cm)
K Recommended 
Cutout Location from 
Floor
13
1
⁄4” (33.7 cm) 12” (30.5 cm) 12” (30.5 cm)
31-10856
01-13 GE
2 D
 CUTOUT FOR INSTALLATION OVER A WARMING DRAWER
NOTE: Install the oven only with specific models listed on the label located on top of the oven.
NOTE: Additional clearances between cutouts may be required. Check to be sure the oven supports 
above the Warming Drawer location do not obstruct the required interior depth and height.
When installing a Warming Drawer below a single or double oven, a separate 120V, 60 HZ, properly 
grounded receptacle must be installed. Refer to installation instructions packed with  
the Warming Drawer for specific installation requirements.
Anti-Tip Block Against 
Rear Wall Per Warming 
Drawer Requirement
2" (5.1 cm) 
Min. 
Per Warming 
Drawer 
Requirement
Continue to Section 3 for DWO with Pedestal. Otherwise, continue to Section 4.
Continue to Section 3.
H
B
C
K
F
G
D
A
J
E
Junction 
Box 
Location 
(junction 
box may 
be located 
in adjacent 
cabinet)
Cutout Depth 
23-1/2” 
(59.7 cm) Min.