Specification

PGP9830SJ
GE Profile
Series 30" Downdraft Gas Cooktop
Specification Created 2/15
InstallIng the ductWork: Use
galvanized or aluminum duct in 6" round
or 3-1/4" x 10" size, or combination of both.
PVC duct or locally approved piping should
be used if installing under a poured concrete
slab. Local building code must be followed in
specifying type and schedule of all duct used.
note: Ductwork must be vented to outside.
Do not vent into a wall, ceiling, crawlspace,
attic or any concealed space. Always use an
appropriate roof or wall cap with damper.
Laundry-type wall caps should never be
used. For maximum efficiency use the short-
est and straightest duct run possible,
with
as few fittings as possible. For satisfactory
performance the duct run should not exceed
100 feet equivalent length. Refer to the table
of equivalent lengths (shown in installation
instructions) for various duct configurations.
Rear Wall VentingDownward Venting
Venting Options
Through Cabinet Toe Space
Inside Wall to Roof Direct to Outside
Between Floor Joist
9-1/8
10-1/8
18-3/4
6-1/8