User Manual
49-80783-6 17
4
 REMOVE ELECTRICAL 
KNOCKOUTS
 Use a flat blade screwdriver, remove the 
appropriate electrical knockout from the back or 
the top of the hood.
5
 REMOVE JUNCTION BOX
 Remove junction box from inside the hood. Set 
the junction box and mounting screws aside.
6
 REMOVE DUCT KNOCKOUT(S) 
FOR VENTED INSTALLATION
 Determine which ducting option to use. 
Using a flat blade screwdriver, remove the 
appropriate duct knockout(s) from the top or 
back of the hood. 
NOTE: If the hood is to be installed in a 
recirculation, non-vented ductless manner, do not 
remove any venting knockouts.
NOTE: For an ENERGY STAR
®
 model, unit must 
be vented mode to be considered ENERGY STAR
®
certified.
7
 ATTACH 
DAMPER/DUCT CONNECTOR
 Attach damper/duct connector over knockout 
opening with two or four (D) screws. Make sure 
damper pivot is nearest to top/back edge of 
hood. Remove any packaging tape to allow 
damper to move freely. 
INSTALLATION PREPARATION
Installation Preparation
3 
1
»4” x 10” Rectangular 
vertical discharge. Remove top 
rectangular duct knockout only.
7” Round vertical discharge. 
Remove semi-circular duct 
knockout and top rectangular 
duct knockout.
3 
1
»4” x 10” Rectangular horizontal 
discharge. Remove rear rectangular 
duct knockout only.
Rectangular Ducting
Round Ducting
Damper (vertical discharge 
position shown)
7RSEDFN 
edge
Tape
7” round 
exhaust 
adaptor
Junction Box
Screws