INstallINg the ductWork: Use
galvanized or aluminum duct in 6" round
or 3-1/4" x 10" size, or combination of both.
PVC duct or locally approved piping should
be used if installing under a poured concrete
slab. Local building code must be followed in
specifying type and schedule of all duct used.
Note: Ductwork must be vented to outside.
Do not vent into a wall, ceiling, crawlspace,
attic or any concealed space. Always
use an appropriate roof or wall cap with
damper. Laundry-type wall caps should
never be used. For maximum efficiency
use the shortest and straightest duct run
possible,
with as few fittings as possible. For
satisfactory
performance the duct run should
not exceed 100 feet equivalent length. Refer
to the table of equivalent lengths (shown in
installation instructions) for various duct
configurations.