Quick Start Guide

Dimensions anD installation information
Dimension and installation information are shown in inches.
Listed by
Underwriters
Laboratories
PGP9830DJ/tJ
GE Profile
Series 30" Downdraft Gas Cooktop
Specification Revised 5/15
INstallINg the ductWork: Use
galvanized or aluminum duct in 6" round
or 3-1/4" x 10" size, or combination of
both. PVC duct or locally approved
piping should be used if installing under
a poured concrete slab. Local building
code must be followed in specifying type
and schedule of all duct used.
Note: Ductwork must be vented to
outside. Do not vent into a wall, ceiling,
crawlspace, attic or any concealed space.
Always use an appropriate roof or wall
cap with damper.
Laundry-type wall caps should never
be used. For maximum efficiency use
the shortest and straightest duct run
possible, with as few fittings as possible.
For satisfactory performance the
duct run should not exceed 100
feet equivalent length. Refer to the
table of equivalent lengths (shown in
installation instructions) for various duct
configurations.
Rear Wall VentingDownward Venting
Venting Options
Through Cabinet Toe Space
Inside Wall to Roof Direct to Outside
Between Floor Joist
9-1/8
10-1/8
18-3/4
6-1/8