Owner manual

Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us” .
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
AM-FSpwSGSeries_EN.doc Nov-13
SG Series
Industrial Brackish Water RO Elements
The S-Series family of proprietary thin-film reverse
osmosis membrane elements is characterized by
high sodium chloride rejection and a smooth, foul-
ing-resistant membrane surface.
SG Brackish Water Elements are used for brackish
water desalination and process stream concentra-
tion.
The SG elements feature either a patented cage or
fiberglass outer wrap and 30mil or 50mil spacer.
Table 1: Element Specification
Membrane
S-Series, Thin-film membrane (TFM*)
Model
Average
permeate flow
gpd (m
3
/day)
1,2
Average NaCl
rejection
1,2
Minimum
NaCl
rejection
1,2
SG2540F30
590 (2.2)
98.5%
97%
SG2540F50
370 (1.4)
98.5%
97%
SG4040C30
2,200 (8.3)
98.5%
97%
SG8040F30
8,400 (31.8)
98.5%
97%
1
Average salt rejection after 24 hours operation.
Individual flow rate may vary ±25%.
2
Testing conditions: 2,000ppm NaCl solution at 225psi (1,551kPa) operating pres-
sure, 77°F (25°C), pH 6.5 and 15% recovery.
Model
Active area
ft
2
(m
2
)
Outer wrap
Part
number
SG2540F30
27 (2.5)
Fiberglass
1207546
SG2540F50
17 (1.6)
Fiberglass
1207547
SG4040C30
100 (9.3)
Cage
1207577
SG8040F30
380 (35.3)
Fiberglass
1207614
Figure 1a: Element Dimensions Diagram (Female)
Table 2: Dimensions and Weight
Model
1
Dimensions, inches (cm)
Boxed
A
B
2
C
3
Weight
lbs (kg)
SG2540F30
40.0
(101.6)
0.75
(1.90) OD
2.4
(6.1)
4
(1.8)
SG2540F50
40.0
(101.6)
0.75
(1.90) OD
2.4
(6.1)
4
(1.8)
SG4040F50
40.0
(101.6)
0.625
(1.59)
3.9
(9.9)
9
(4.1)
SG4040C30
40.0
(101.6)
0.625
(1.59)
3.9
(9.9)
9
(4.1)
SG8040F30
40.0
(101.6)
1.125
(2.86)
7.9
(20.1)
29
(13.2)
1
These elements are dried then bagged before shipping.
2
Internal diameter unless specified OD (outside diameter).
3
The element diameter (dimension C) is designed for optimum performance in GE
pressure vessels. Other pressure vessel dimension and tolerance may result in
excessive bypass and loss of capacity
Table 3: Operating and CIP Parameters
Typical Operating Flux
5 20 GFD (8 34 LMH)
Maximum Operating Pressure
600psi (4,137kPa) if T < 95°F (35°C)
435psi (3,000kPa) if T > 95°F (35°C)
Maximum Temperature
Continuous Operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)
pH Range
Optimum Rejection: 5.5-7.0,
Continuous Operation: 2.0-10.0,
Clean-In-Place (CIP): 1.0-10.5
Maximum Pressure Drop
Over an element 15psi (103kPa)
per housing: 60psi (414kPa)
Chlorine Tolerance
500+ ppm hours,
dechlorination recommended
Feedwater
NTU < 1
SDI < 5