User Manual

Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
FS1287EN.doc Nov-13
PW Series
Industrial Ultrafiltration Post treatment of RO and NF
The P-Series family of polyethersulfone ultrafiltra-
tion membrane elements are characterized by a
10,000 molecular weight cut-off and greater than
96% rejection of Cytochrome-C (13,300 MW pro-
tein). PW Elements are used for pretreatment of
process water, post treatment of ultrapure
water and for the removal of organics.
Table 1: Element Specification
Membrane
P-Series, Polyethersulfone
Model
Spacer mil
(mm)
Active area
ft
2
(m
2
)
Outer wrap
PW2540C30
30 (0.76)
16 (1.5)
Cage
PW2540F30
30 (0.76)
25 (2.3)
Fiberglass
PW2540F50
50 (1.27)
17 (1.6)
Fiberglass
PW4025C
50 (1.27)
50 (4.6)
Cage
PW4025T
50 (1.27)
50 (4.6)
Tape
PW4040C30
30 (0.76)
91 (8.4)
Cage
PW4040C50
50 (1.27)
62 (5.8)
Cage
PW4040F30
30 (0.76)
85 (7.9)
Fiberglass
PW8040C50
50 (1.27)
264 (24.5)
Cage
PW8040F30
30 (0.76)
354 (39.2)
Fiberglass
PW8040F50
50 (1.27)
279 (25.9)
Fiberglass
PW8340C50
50 (1.27)
290 (27)
Cage
Figure 1: Element Dimensions Diagram Female
Figure 2: Element Dimensions Diagram Male
Table 2: Dimensions and Weight
Model
1
Dimensions, inches (cm)
Boxed
A
B
2
C
3
Weight
lbs (kg)
PW2540
40.0
(101.6)
0.75
(1.9) OD
2.4
(6.1)
4
(1.8)
PW4025
25.0
(63.5)
0.625
(1.59)
3.9
(9.9)
5
(2.3)
PW4040C
38.75
(98.4)
0.625
(16)
3.9
(9.8)
9
(4.1)
PW4040F
40.0
(101.6)
0.75
(1.90) OD
3.9
(9.9)
8
(3.5)
PW8040
40.0
(101.6)
1.125
(2.86)
7.9
(20.1)
29
(13.2)
PW8340
40.0
(101.6)
1.138
(2.89)
8.3
(21.1)
42
(19.1)
1
These elements are bagged dry before shipping.
2
Internal diameter unless specified OD (outside diameter).
3
The element diameter (dimension C) is designed for optimum performance in GE
pressure vessels. Other pressure vessel dimension and tolerance may result in
excessive bypass and loss of capacity.
Table 4: Operating and CIP parameters
Typical Operating Pressure
80-135 psig (555 931 kPa)
Typical Operating Flux
10-25GFD (15-40LMH)
Maximum Operating Pressure
200 psig (1,379 kPa)
Maximum Temperature
Continuous operation: 122°F (50°C)
Clean In Place (CIP): 122°F (50°C)
pH Range
Continuous operation: 4.0-11.0,
Clean In Place (CIP): 2.0-11.5
Maximum Pressure Drop
Over an element: 12 psig (83 kPa)
Per housing: 50 psig (345 kPa)
Chlorine Tolerance
5,000+ ppm-days