Owner manual

Fact Sheet Page 2
CH0000EN 0411
Materials of Construction
High-pressure piping 316 Stainless Steel PN 25
Low-pressure piping PVC PN 10/16
Frame Painted blue carbon steel
Enclosure IP 55
Clamps/fittings Zinc-plated
Membrane Elements and Housings
Membrane Model AK8040F-400, AG8040F-400
AK-400 or AG-400
Style Spiral-wound elements
Manufacturer GE
Membrane type TFC (Polyamide)
Membrane Elements and Housings
continued
Average membrane flux 18-28 lmh
Membrane rejection 99.0-99.5 %
Manufacturer GE
Housing material FRP
Housing Pressure Rating 20 or 30 Bar
Cartridge Filtration
Housing model GE HX-0740-80-V316
Housing material 316 Stainless Steel
Cartridge filter 1-micron nominal, ROsave.Z*s
GE PRO EU Models
MODEL
PRO-11-EU
PRO-23-EU
PRO-34-EU
PRO-68-EU
PRO-102-EU
Permeate Rate
1
:
Concentrate Rate:
Concentrate Recycle:
Feed Rate:
8-12 m
3
/hr
1-5 m
3
/hr
3 m3/hr
9-17 m
3
/hr
17-25 m
3
/hr
3-11 m
3
/hr
3 m3/hr
20-36 m
3
/hr
25-37 m
3
/hr
4-15 m
3
/hr
NA
29-52 m
3
/hr
51-75 m
3
/hr
9-32 m
3
/hr
NA
60-107 m
3
/hr
76-112 m
3
/hr
7-48 m
3
/hr
NA
89-160 m
3
/hr
Pumps and Motors
Manufacturer:
Quantity:
Motor Power and type:
Design boost pressure:
Grundfos
1
11 kW-15KW; IP55
10-16 bar
Grundfos
1
15KW-22 kW; IP55
10-16 bar
Grundfos
1
22KW-30KW; IP55
10-16 bar
Grundfos
2
22KW-30 kW; IP55
10-16 bar
Grundfos
2
30KW-45 kW; IP55
10-16 bar
Membrane Elements and Housings
Membranes Quantity:
Memb. Housing Style:
Banking Arrangement:
12
4 element long,
4 port
21 or 111
24
4 element long,
4 port
42 or 321
36
6 element long,
4 port
42 or 321
72
6 element long,
4 port
84 or 642
108
6 element long,
4 port
126 or 963
Cartridge Filtration
Housing Model:
Housing Quantity:
Cartridge Filter Model:
Cartridge Filter Length:
Cartridge Filter Qtity:
HX-0740-80-V-316
1
RO.Zs01-40XK
102 cm (40”)
7 per housing,
7/change out
HX-0740-80-V-316
1
RO.Zs01-40XK
102 cm (40”)
7 per housing,
7/change out
HX-0740-80-V-316
2
RO.Zs01-40XK
102 cm (40”)
7 per housing,
14/change out
HX-0740-80-V-316
3
RO.Zs01-40XK
102 cm (40”)
7 per housing,
21/change out
HX-0740-3.0-V-316
4
RO.Zs01-40XK
102 cm (40”)
7 per housing,
28/change out
Installation and Utility Requirements
Inlet:
Permeate:
Concentrate:
Inlet Water Pressure:
Air Pressure:
Drain to be Sized for:
Power:
Control Circuit
DN 50 flange
DN 40 flange
DN 25 flange
2 bar, min.
6 bar, oil-free
18 m
3
/hr
400 VAC, 3-phase, 50Hz
230 VAC, 1-phase, 50Hz
DN 80 flange
DN 80 flange
DN 40 flange
2 bar, min.
6 bar, oil-free
31 m
3
/hr
400 VAC, 3-phase, 50Hz
230 VAC, 1-phase, 50Hz
DN 80 flange
DN 80 flange
DN 40 flange
2 bar, min.
6 bar, oil-free
31 m
3
/hr
400 VAC, 3-phase, 50Hz
230 VAC, 1-phase, 50Hz
DN 150 flange
DN 100 flange
DN 65 flange
2 bar, min.
6 bar, oil-free
91 m
3
/hr
400 VAC, 3-phase, 50Hz
230 VAC, 1-phase, 50Hz
DIN 150 flange
DIN 150 flange
DIN 80 flange
2 bar, min.
6 bar, oil-free
136 m
3
/hr
400 VAC, 3-phase, 50Hz
230 VAC, 1-phase, 50Hz
Skid
Height:
Width:
Depth:
Weight estimates:
Operating:
Shipping:
201 cm
500 cm
95 cm
1870 kg
1550 kg
240 cm
500 cm
95 cm
3355 kg
2350 Kg
242 cm
700 cm
95 cm
4420 kg
3005 Kg
247 cm
710 cm
140 cm
8110kg
4960 Kg
247 cm
710 cm
170 cm
11430 kg
6740 Kg
1
At design temperature