Instruction Manual

Fact Sheet Page 2
Membrane Elements and Housings
Membrane model AG8040F
Style Spiral-wound elements
Membrane manufacturer GE
Membrane type TFC (Polyamide)
Average membrane flux
1
28 lmh (16.4 gfd)
Membrane rejection 99.0-99.6%
Housing manufacturer Wave Cyber or Equal
Housing material FRP
1
Flux can be reduced to 25.5 lmh (15 gfd) by using 400sqft
elements. Rated flow can be further reduced by up to 20%.
Cartridge Filtration
Housing model 7 Rounds, 102cm (40“)
Housing material 316 SS
Cartridge filter 1-micron nominal, ROsave.Z*s
GE PRO-AP-60hz Models
MODEL
PRO-11-AP-60
PRO-23-AP-60
PRO-34-AP-60
PRO-45-AP-60
PRO-102-AP-60
Permeate rate:
2
Concentrate Rate:
Feed Rate:
11.4 m
3
/hr
3.8 m
3
/hr
15.1 m
3
/hr
22.7 m
3
/hr
7.5 m
3
/hr
30.2 m
3
/hr
34.1 m
3
/hr
11.4 m
3
/hr
45.4 m
3
/hr
45.4 m
3
/hr
14.9 m
3
/hr
60.4 m
3
/hr
68.1 m
3
/hr
22.7 m
3
/hr
90.8 m
3
/hr
102.2 m
3
/hr
34.1 m
3
/hr
136.3 m
3
/hr
Pumps and Motors
Manufacturer:
Model:
Quantity:
Motor HP:
Design Flow Rate:
Design boost pressure:
Xylem
15SV07N1106T
1
11 kW
18.2 m
3
/hr
12.4 bar
Xylem
33SV4N1856T
1
18.5 kW
32.4 m
3
/hr
12 bar
Xylem
46SV4N3006T
1
30 kw
45.4 m
3
/hr
12.6 bar
Xylem
66SV4/2AN3706T
1
37 kw
64.9 m
3
/hr
12 bar
Xylem
46SV4N3006T
2
2 x 30 kW
90.8 m
3
/hr
12.6 bar
Xylem
66SV4N3706T
2
2 x 37 kW
136.3 m
3
/hr
13.6 bar
Membrane Elements and Housings
Membranes quantity:
Memb. housing style:
Banking Arrangement:
12
4 element long, 4 port
111
24
4 element long, 4 port
321
36
6 element long, 4 port
321
48
4 element long, 4 port
642
72
6 element long, 4 port
642
108
6 element long, 4 port
963
Cartridge Filtration
Cartridge Filter:
Filter Length:
Filter Quantity:
RO.Zs01-40
102 cm (40)
7 per housing
7/change out
RO.Zs01-40
102 cm (40)
7 per housing
7/change out
RO.Zs01-40
102 cm (40)
7 per housing
14/change out
RO.Zs01-40
102 cm (40)
7 per housing
14/change out
RO.Zs01-40
102 cm (40)
7 per housing
21/change out
RO.Zs01-40
102 cm (40)
7 per housing
28/change out
Installation and Utility Requirements
Inlet:
Permeate:
Concentrate:
Inlet Water Pressure:
Air Pressure:
Drain to be Sized for:
Power:
Control Circuit:
ANSI 2" flange
ANSI 2" flange
ANSI 1.5" flange 2.1 2
bar min.
6.9 bar, oil-free
15.1 m
3
/hr
380-480 VAC, 3-ph, 60Hz
110-230 VAC, 1-ph, 60Hz
ANSI 3" flange
ANSI 3" flange
ANSI 1.5" flange
2 bar min.
6.9 bar, oil-free
30.2 m
3
/hr
380-480 VAC, 3-ph, 60Hz
110-230 VAC, 1-ph, 60Hz
ANSI 3" flange
ANSI 3" flange
ANSI 1.5" flange
2 bar min.
6.2 bar, oil-free
45.4 m
3
/hr
380-480 VAC, 3-ph, 60Hz
110-230 VAC, 1-ph, 60Hz
ANSI 4" flange
ANSI 3" flange
ANSI 2" flange
2 bar min.
6.2 bar, oil-free
60.4 m
3
/hr
380-480 VAC, 3-ph, 60Hz
110-230 VAC, 1-ph, 60Hz
ANSI 4" flange
ANSI 4" flange
ANSI 2" flange
2 bar min.
6.9 bar, oil-free
90.8.0 m
3
/hr
380-480 VAC, 3-ph, 60Hz
110-230 VAC, 1-ph, 60Hz
ANSI 6" flange
ANSI 4" flange
ANSI 3" flange
2 bar min.
6.9 bar, oil-free
136.3 m
3
/hr
380-480 VAC, 3-ph, 60Hz
110-230 VAC, 1-ph, 60Hz
Skid
Approx.Height:
Approx. Width:
Approx.Depth:
Approx. Shipping
Weight :
2000 mm
800 mm
4900 mm
1543 kg
2200 mm
900 mm
5050 mm
2132 kg
2240 mm
950 mm
6850 mm
2722 kg
2240 mm
1250 mm
5200 mm
3085 kg
2420 mm
1400 mm
6950 mm
4490 kg
2475 mm
1850 mm
7080 mm
6124 kg
2
Maximum permeate rate listed at design temperature. Permeate rate can be reduced by up to 20%