Instruction Manual

Page 2 FspwMemtrexKM_EN Nov-09
Table 4: Integrity Testing
Micron Rating Specification
0.2 µm ≤ 50 cc/min at 30 psig (2.07 bar)
0.45 µm ≤ 50 cc/min at 15 psig (1.03 bar)
0.65 µm ≤ 50 cc/min at 12 psig (0.83 bar)
Air diffusion per 10” module after saturation with clean water
Table 5: Flow Performance in Clean Water
1
1
Data based on 10” length filter
Additional Information
• Memtrex KM filters may be autoclaved or in situ
steam sterilized (up to 257°F [125°C], 30-minute
cycles) for a maximum accumulated exposure
of 10 hours. Alternately, the filters may be sani-
tized with compatible chemical agents.
• GE certifies that the material contained in its
Memtrex KM pleated filters meet U.S. FDA
requirements for food contact under the appli-
cable regulations in 21 CFR. For further informa-
tion, contact GE technical services. Memtrex
MKM filters meet the test criteria for USP class
VI-121°C Plastics.
• Aqueous extracts from Memtrex KM filters con-
tain less that 0.25 EU/ml. The filters typically
exhibit low levels of non-volatile residues.
• GE filter cartridges are designed and manufac-
tured for resistance to a wide range of chemical
solutions. Conditions will vary with each appli-
cation and users should carefully verify chemi-
cal compatibility. Please contact your GE
distributor for more information.
• Table 6 provides additional ordering information.
Table 6: Ordering Information
Type Micron Rating Nominal Cartridge Length End #1 Adapter End #2 Adapter Elastomer Material
MKM 92 = 0.2 µm
94 = 0.45 µm
96 = 0.65 µm
1 = 10 in. (25.4 cm)
2 = 20 in. (50.8 cm)
3 = 30 in. (76 cm)
4 = 40 in. (101.5 cm)
A = Open End Gasket
B = 120 O-Ring
C = 213 O-Ring
E = 222 O-Ring
F = 226 O-Ring
J = 020 O-Ring
Q = 222 O-Ring
Stainless Steel Insert
Z = 226 O-Ring
Stainless Steel Insert
A = Open End Gasket
B = 120 O-Ring
C = 213 O-Ring
G = Closed End Cap
H = Fin Adapter
B = Buna-N
E = EPDM
S = Silicone
T = Teflon
2
Encapsulated
(Only in 222
and 226 Sizes
V = Viton
2
2
Teflon and Viton are registered trademarks of DuPont.
Service Flow
Pressure Drop
MKM92
MKM94
MKM96
bar psid
0.21 3
0.17 2.5
0.14 2
0.10 1.5
0.07 1
0.03 0.5
00
Memtrex KM Pleated Filter
gpm 123 4 56
lpm 3.8 7.6 11.4 15.2 19.0 22.8
Service Flow
Pressure Drop
MKM92
MKM94
MKM96
bar psid
0.21 3
0.17 2.5
0.14 2
0.10 1.5
0.07 1
0.03 0.5
00
Memtrex KM Pleated Filter
gpm 123 4 56
lpm 3.8 7.6 11.4 15.2 19.0 22.8