Instruction Manual
Page 2 FS1682EN Aug-07
General Properties
Trailer
Length: 48’-0” (14.6 meters)
Height: 13’-6” (4.1 meters)
Width: 8’-3” (2.5 meters)
Gross operating weight (approx.): 57,000 lbs. (25,9i00 kg)
Gross shipping weight (approx.): 30,700 lbs. (13,900 kg)
Connections
Connection Type: Victaulic/Flange
Inlet: 8 inch (200 mm)
Outlet (Filtrate): 8 inch (200 mm)
Backwash Waste: 8 inch (200 mm)
Misc. Waste: 3 inch (75 mm)
Electrical
Service: 480 VAC, 3 phase
Breaker size: 250 amp
Installed KVA: 148 KVA
Heating:
Climate controlled via standard
electric HVAC
PLC Instrumentation
Parameter Inlet Outlet GE Fanuc PLC
Flow X X
Pressure X X
Temperature X
Turbidity X X
Analog (4-20 mA) to customer
tie-in and/or discrete tank level
for automatic shut down and
control
System on Board
Membrane: PVDF Hollow Fiber Membrane
Air Compressor: Provides instrument air
Max. Water Temp.: 104ºF (40ºC)
Min. Water Temp.: 32ºF (0ºC)
Inlet Pressure: 30 psig (2 bar) to 45 psig (3 bar)
Min. Inlet Pressure: 5 psig (.3 bar)
Outlet Pressure: 30 psig (2 bar) to 90 psig (6.1 bar)
Max. Inlet Turbidity: 100 NTU/peak to 500 NTU
Maximum Inlet Water TSS: 300 mg/l
Influent Flow: Up to 1100 gpm (250 m
3
/hr)
Effluent Flow: Up to 800 gpm (181 m
3
/hr) continuous
Waste Flow: 5 gpm (1.1 m
3
/hr) max. intermittent
Effluent Turbidity: <0.05 NTU maximum, <0.2 NTU typical
SDI: <3 maximum, <2.5 typical