Fact Sheet
E-Cell MK-2 PharmHT
Heat Sanitizable Ultrapure Water for Pharmaceutical Industry
Description and Use
E-Cell* electrodeinization (EDI) technology is setting
the industry standard for chemical-free, ultra-pure
water production. E-cell stacks offer a robust alter-
native to mixed bed technology.
The PharmHT model series is designed to deliver
high purity water for pharmaceutical applications
where heat sanitization is required, rated for 60 cy-
cles of sanitization at 80°C.
The modular design allows configuration of single
or multiple stacks to provide a cost-effective treat-
ment across all flow requirements.
Parameter US Units SI Units
Product Water
Flow rate per stack 7.0 to 20 gpm 1.6 to 4.5 m
3
/h
Resistivity
> 10 MOhm-cm > 10 MOhm-cm
Feed Water (RO Permeate or Equivalent)
Feed TEA (per E-calc
Projection software)
< 39 ppm as CaCO
3
* < 39 mg/L as CaCO
3
*
Silica (SiO
2
)
< 500 ppb < 500 ug/L
TOC
< 0.5 ppm < 0.5 mg/L
Operational Temperature Range
40 to 100°F 4.4 to 38°C
Hardness
< 0.5 ppm < 0.5 mg/L
*Actual performance may vary depending on site conditions. Reference E-Calc projection software to verify actual performance.
Operating Parameters
Nominal recovery 90% to 95% 90% to 95%
DC power consumption (nom.) 0.2 to 1.5 kWh/1000 US gal 0.05 to 0.4 kWh/m
3
Feed pressure 50 to 100 psig 3.4 to 6.9 bar
Pressure drop 20 to 45 psid 1.4 to 3.1 bar
Dimensions 12” W x 19” D x 24” H 30cm W x 48cm D x 61cm H
Weight 202 lb 92 kg
Heat Sanitization Parameters (RO Permeate or Equivalent)
Dilute flow rate per stack 7 to 10 gpm 1.6 to 2.3 m
3
/h
Concentrate flow rate per stack 2 to 3 gpm 450 to 680 L/h
Inlet Sanitization Temperature
< 185°F < 85°C
Feed Pressure < 30 psig < 2.1 bar