User guide

Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
FS1138EN.doc Jul-13
EZ2 Kit, 50 Hz
Reverse Osmosis Machine 1.7-9.6 cubic meters per day
Figure 1: EZ2 Kit
When you mention reverse osmosis (RO), GE Water
& Process Technologies is the first name to come to
mind. Our E-series RO machines (Figure 1) are de-
signed for durable operation, high quality product
water production, easy installation and straightfor-
ward control.
General Properties
Typical Applications
Process ingredient water
Safe drinking water
Spot free rinse water
Ion exchange pre-treatment
R & D lab use
Standard Economy Features
1-micron pre-filter
Automatic inlet shut-off valve
Remote machine on/off capability
Operating pressure gauge
Flow control center including concentrate and
recycle valves
Brass pump
Deluxe (DLX) Features In addition to ECN
Features
Low inlet pressure switch
Conductivity meter
Stainless steel pump
Permeate and concentrate flow meters
Table 1: Operating Parameters
Operating Pressure
14-15 bar
Maximum Recovery
50%
Nominal Rejection
95-98%
Operating Temperature
13-30°C (55-86°F)
Minimum Inlet Pressure
2 bar
Design Temperature
25°C (77°F)