DL 455a362e561c07b96069ab446b42
6
49-80152-7
Advance Planning
DETERMINE INSTALLATION HEIGHT, DUCT COVER ACCESSORIES
Restaurant-Style Hoods
without Warming Shelf
Installed
Restaurant-Style Hoods with
Shelf Installed
Actual
Ceiling
Height
*Possible
Hood
Installation
Height
6"
Duct
Covers
Duct
Covers
*Possible
Hood
Installation
Height
6"
Duct
Covers
Duct
Covers
7' 11" 31" 1 1 37" 1
8' 0"
8' 0"
32" 1 1 32"
38"
11
1
8' 1" 33" 1 1 33" 1 1
8' 2" 34" 1 1 34" 1 1
8' 3" 35" 1 1 35" 1 1
8' 4"
8' 4"
30"
36" 1
2
1 36" 1 1
8' 5" 31" 2 37" 1 1
8' 6"
8' 6"
32" 2 32"
38" 1
2
1
8' 7" 33" 2 33" 2
8' 8" 34" 2 34" 2
8' 9" 35" 2 35" 2
8' 10"
8' 10"
30"
36"
12
2 36" 2
8' 11" 31" 1 2 37" 2
9' 0"
9' 0"
32" 1 2 32"
38"
12
2
9' 1" 33" 1 2 33" 1 2
9' 2" 34" 1 2 34" 1 2
9' 3" 35" 1 2 35" 1 2
9' 4"
9' 4"
30"
36" 1
3
2 36" 1 2
9' 5" 31" 3 37" 1 2
9' 6"
9' 6"
32" 3 32"
38" 1
3
2
9' 7" 33" 3 33" 3
9' 8" 34" 3 34" 3
9' 9" 35" 3 35" 3
9' 10" 30"
36"
13
3 36" 3
9' 11" 31" 1 3 37" 3
10' 0"
10' 0"
32" 1 3 32"
38"
13
3
These vent hoods must be installed 30" min. to
36" max. above the standard 36" high cooking
surface. When installed with the warming
shelf, allow 32" min. to 38" max. clearance. The
exact hood installation height is determined
by the ceiling height.
Measure the exact ceiling height.
Review the chart at right to determine the
range of possible hood installation heights
that can be accomplished with one or more
duct covers.
3. Increase or decrease hood installation
KHLJKWWRDFFRPPRGDWHWKH¿[HGRU
duct covers.
4. Duct covers may be stacked, in various
combinations, to reach ceiling heights.
*Based on 36" countertop height.
Note: Additional duct covers may be used to reach higher ceilings.
Note: When determining the installation
height, consideration must be given to the use
of the warming shelf.
32" Min.
38" Max.
30" Min.
36" Max.
10"
Ceiling
Height
to Floor
Duct Cover(s)
Duct Cover(s)
10"
Ceiling
Height
to Floor