Appliance Trim Kit User Manual
Table Of Contents
- Chapter 1 Overview
- Chapter 2 C400 Panel Controller Hardware
- General Information
- Genius Panel Controller (C400)
- Specifications
- Overview of Connections and Operational Elements
- VDC Power Supply (item 2, Figure 2-2)
- IF0 - RS-232, Non-isolated (item 3, Figure 2-2)
- Genius Bus Connector, Isolated (item 4, Figure 2-2)
- Mode Switch (item 6, Figure 2-2)
- Device Number Switches (item 8, Figure 2-2)
- Lithium Battery (item 7, Figure 2-2)
- Reset Button (item 9, Figure 2-2)
- Operating the C400 Controller
- Chapter 3 Quick Start
- Calling the Setup Program
- Language Selection
- Installation Menu
- Pull-Down Menus (Main Menu)
- Window Name
- Selection Windows
- Context-Sensitive Help Screens
- Screen Elements
- Connection to a GE Fanuc PLC via Genius
- Internal Connection
- Genius Internal Connection
- Picture 1
- Picture 2
- Picture 3
- Genius Device Connection
- Genius Internal Connection
- Internal Connection
- Picture for a Communications Error
- Picture Binding Overview
- Picture List Organization
- Chapter 4 Configuring Communication with the PLC
- Chapter 5 PCS Connection Editor
- Chapter 6 Demo Project
- Appendix A Cabling Information
- Appendix B Errors/Troubleshooting
- Index

GFK-1115 Chapter 6 Demo Project 6 - 61
6
Editing the Connections
All of the variables used in the project must be assigned to a certain PLC address in the
connection editor. General information on operating the connection editor can be found in the
PANELWARE™ Configuration Software Reference Manual (GFK-0849).
Access the connection list from the main menu, either by selecting the Connection option in the
Edit menu, or by using key combination Ctrl + C:
Internal Connection
You can display all of the internal variables used in your project. Move the cursor in the
connection list to the connection DI Internal and press F5 VAT or ↵↵:
If you have made all entries correctly, your screen should look like the screen shown above.
Compare the variable names and the corresponding Panel data types. If the variable assignment
table is different from the one above, make the required changes. Possible errors and their
corrections are:
• Wrong Name: Change the address in the respective picture/field.
• Wrong Panel Data Type: You have used a field with the incorrect data type in a picture.
Delete the field and its entry in the VAT and then insert the desired field.
Pressing F10 Exit or Esc closes the variable assignment table for the DI Internal connection.