Alerting
The PPU Tag and the Remote Alarm unit will both advise the operator of a number of
conditions with visual, audible and vibratory indications in the following ways:
Event
Indication
Detail
CAS-GPS alert
One pulse, repeated
CAS-GPS Electromagnetic
Zone 2 alert
Three pulses, repeated
CAS-GPS Electromagnetic
Zone 1 alert
Continuous
Entry into safe zone
Three pulses (short gap)
Vehicle pairing clear
(PPU ONLY)
Two pulses, repeated
PPU set not paired
One pulse, repeated
Low Battery
Two pulses, repeated
Self-test fail
One pulse, repeated
Self-test pass
Three pulses (long gap)
Man Down alarm
Two pulses, repeated
Communications Jammed
Five pulses, repeated
Instructions
1. Test the PPU before use with PPU Test Station (PROD1006/PROD1082).
2. Geofences, Alarm Logic and Information exchange between the PPU and
the CAS-Web occur whilst charging within the PPU Gang Docking Station.
3. To unclip the Remote Alarm from your helmet, depress the remote alarm
spring levers located on either side of the alarm.
4. Re-fit Remote Alarm to the PPU Tag & place tag set on charge as per the
charging instructions above, (confirm charge cycle commences).
5. Do not use damaged or malfunctioning PPU equipment.
Disposal
The PPU Tag and Remote Alarm units both contain Li-Ion batteries and must be
disposed of in accordance with local regulations and statutes.