CAS GPS Installation Manual Rev G1
2/17/2016
Mounting Locations & Cable Runs
Follow existing cable runs where possible
All cables to be secured using P-Clamps where possible
Cable ties should be used as a last resort where there is no provision for P-Clamps
Ensure cable ties are cut flush to avoid sharp edges
Cables should be secured at a minimum every 300mm
Avoid running cables near hot spots and pinch points
Glands should be used on cables running through bulkheads
It is recommended that a service loop be created on all the Antenna Coax Cables
this will especially aid in servicing of the system. i.e. Break in termination at either
end of the Coax cables.
Service loops are acceptable in the Coax and Display cables. Ensure if a service
loop is placed in the Coax Antenna cable that it is placed in a position that it is not
going to create a hazard, also ensure the service loop radius is not to small.
If mounting through a blind panel the supplied Nutserts should be used to enable
easy removal for servicing