User's Manual

Collision Avoidance System: CAS-CAM/RF® Operating Instructions
Document Number: CAS-CAM_RF Operating Instructions (with FCC
precautions)_18June2010.doc
Page 72 of 126
Issue: E
10.1.11.8 Alarm Specifications
Alarm Conditions: 1. New object(s) move into HV Detection Zone(s)
2. Object(s) in HV Detection Zone when HV re-engages gear
Alarm Modes: 1. Reverse Gear
Fully programmable Front & Rear & Side detection
ranges & audible alarms for different object types (e.g.
HV, LV, SO, PT, TS), location (front or rear or side) and
direction of travel with flashing object text
2. Forward Gear
Fully programmable Front & Rear detection & Side
ranges & audible alarms for different object types (e.g.
HV, LV, SO, PT, TS), location (front or rear or side) and
direction of travel with flashing object text
3. Park / Neutral Gear
Fully programmable Front & Rear & Side detection
ranges & audible alarms for different object types (e.g.
HV, LV, SO, PT, TS), location (front or rear or side) and
direction of travel with flashing object text
Alarm Zones: Programmable detection zones for different object types (e.g. HV,
LV, SO, PT, TS) with programmable ranges (0-80m).
Alarm Output: Audible alarm and flashing object text (detections) on Display for
both FRONT and REAR and SIDES. Fully programmable alarms
based on object type, range, location (front or rear or sides),
direction of travel and speed.
Alarm Tones: Pulsed audible alarm @ 0.5Hz
Alarm Cancellation: Driver presses ‘CONFIRM’ key or object moves out of Detection
Zone(s).
Table 37: Heavy Vehicle Alarm Specifications