GE MultiLink Submittal
Matching Tables
Adapters
GEA Part #
A 1/4” to 3/8” (Liquid line for ports C & D) WJ01X23925
B 3/8” to 5/8” (Vapor line for port C) WJ01X23924
C 1/2” to 5/8” (Vapor line for port D) WJ01X23932
D 3/8” to 1/2” (Vapor line for port C) WJ01X26853
E 1/2” to 3/8” (Vapor line for port C or D) WJ01X26854
ASH218JCDDA
Combinations
Required
Adapter
Port B Port A
1/4" x 3/8" 1/4" x 3/8"
Two
Zone
7 7 -
9 7 -
9 9 -
12 7 -
12 9 -
12 12 -
No adapter is shipped
with ASH2
ASH324JCDDA
Combinations
Required
Adapter
Port C Port B Port A
MS: 1/4" x 3/8"
EH: 1/4" x 1/2"
1/4" x 3/8" 1/4" x 3/8"
Two
Zone
7 7 - - - -
9 7 - - - -
9 9 - - - -
12 7 - - - -
12 9 - - - -
12 12 - - - -
18 7 - - - D
18 9 - - - D
18 12 - - - D
Three
Zone
7 7 7 -
9 7 7 -
9 9 7 -
12 7 7 -
9 9 9 -
12 9 7 -
12 9 9 -
12 12 7 -
18 7 7 D
12 12 9 -
ASH324JC ships with adapter D
ASH436JCDDA
Combinations
Required
Adapter
Port D Port C Port B Port A
1/4" x 1/2" 1/4" x 3/8" 1/4" x 3/8" 1/4" x 3/8"
Two
Zone
18 9 - - - - - - -
18 12 - - - - - - -
24 7 - - - - - - C, A
24 9 - - - - - - C, A
24 12 - - - - - - C, A
18 18 - - - - - - D
18 24 - - - - - - A, B
24 24 - - - - - - B, C, A, A
Three
Zone
9 9 9 - - - E
12 9 7 - - - E
12 9 9 - - - E
12 12 7 - - - E
18 7 7 - - - -
12 12 9 - - - E
18 9 7 - - - -
18 9 9 - - - -
12 12 12 - - - E
18 12 7 - - - -
24 7 7 - - - C, A
18 12 9 - - - -
24 9 7 - - - C, A
24 9 9 - - - C, A
18 12 12 - - - -
24 12 7 - - - C, A
24 12 9 - - - C, A
24 12 12 - - - C, A
18 18 12 - - - D
Four
Zone
7 7 7 7 E
9 7 7 7 E
9 9 7 7 E
12 7 7 7 E
9 9 9 7 E
12 9 7 7 E
9 9 9 9 E
12 9 9 7 E
12 12 7 7 E
12 9 9 9 E
18 7 7 7 -
12 12 9 7 E
18 9 7 7 -
12 12 9 9 E
12 12 12 7 E
18 9 9 7 -
18 12 7 7 -
24 7 7 7 C, A
12 12 12 9 E
24 9 7 7 C, A
12 12 12 12 E
18 12 9 9 -
ASH436JC ships with adapters D, E