GE Endure Series Submittal
ENDURE SERIES SUBMITTAL
Rev. April 2020
Outdoor Unit
Compressor DC inverter Driven Rotary
Uncrated Dimension (HxWxD)
30 x 36 1/4 x 15 1/8 in
762 x 920 x 385 mm)
Crated (HxWxD)
34 x 42 3/4 x 19 1/8 in
(863 x 1085 x 487 mm)
Outdoor Sound Rating dB 52
Heat Exchanger Fin Type Blue Fin
Weight (Ship/Net) 154.3/133.4 lbs
Factory Refrigerant Charge R-410A (82.9 oz)
18000 BTU/HR WALL MOUNTED INVERTER DRIVEN HEAT PUMP SYSTEM
ASH118URDSD / ASYW18URDWD
Capacity and power usage are measured under the assumption of indoor humidity of 46%
HEATING CAPACITY DATA
Outdoor
Air Temp
DB
Indoor Set Temperature
60
O
F (16
O
C) 70
O
F (21
O
C) 77
O
F (25
O
C)
Maximum Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
-31
O
(-35
O
) 7,050 3,010 7,400 3,070 7,500 3,310
-22
O
(-30
O
) 16,450 2,870 17,200 2,950 17,450 3,200
-15
O
(-26
O
) 19,150 3,580 20,000 3,760 20,300 3,820
-4
O
(-20
O
) 21,000 3,880 22,000 3,980 22,450 4,010
5
O
(-15
O
) 23,950 3,150 25,000 3,230 25,400 3,260
17
O
(-8
O
) 20,110 2,260 21,000 2,320 21,450 2,360
47
O
(8
O
) 24,950 2,490 26,000 2,580 26,500 2,640
COOLING CAPACITY DATA
Outdoor
Air Temp
DB
Indoor Set Temperature
70
O
F (21
O
C) 75
O
F (24
O
C) 80
O
F (27
O
C)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
14
O
(-10
O
) 17,800 1,490 17,000 1,420 16,650 1,390
65
O
(18
O
) 15,300 1,010 14,600 950 14,300 890
75
O
(24
O
) 18,000 1,260 17,200 1,210 16,400 1,160
85
O
(29
O
) 21,000 1,630 20,000 1,570 19,100 1,510
95
O
(35
O
) 23,000 1,860 21,850 1,800 20,850 1,740
105
O
(41
O
) 20,750 1,740 19,750 1,680 18,650 1,620
115
O
(46
O
) 17,600 1,670 16,700 1,590 15,900 1,520
1U18EH2VHD
36 1/4 (920)
30 (792)
15 1/8 (385)
AW18EH2VHD
44 3/8 (1126)
9 (230)
13 1/4 (337)
Capacity and power usage are measured under the assumption of indoor humidity of 46%
Indoor Unit
Uncrated Dimension (HxWxD)
13 1/4 x 44 3/8 x 9 in
(337 x 1126 x 230 mm)
Crated (HxWxD)
16 1/2 x 47 1/2 x 13 1/2 in
(418 x 1206 x 342 mm)
Airflow CFM
(Turbo/High/Med/Low/Quiet)
636/541/436/330/259
Indoor Sound Level dB
(Turbo/High/Med/Low/Quiet)
47/41/38/35/29
Motor Rating (HP) 0.07
Heat Exchanger Fin Type Blue Fin
Weight (Ship/Net) 45.2/36.6 lbs