GE Endure Series Submittal
ENDURE SERIES SUBMITTAL
Rev. April 2020
Electrical Requirement
Power Supply
208/230V, 1 Phase,
60 HZ
Operating Voltage Range 187~253 VAC
Recommended Fuse/Breaker Size 30A
MCA 20A
Cooling Performance
Rated Cooling Capacity 18,000 BTU
Cooling Capacity Range 8,500~21,000 BTU
Rated Power input 1,358 W
SEER 23.0
EER 13.0
Moisture Removal 4.2 Pt./h
Heating Performance
Rated Heating Capacity 20,000 BTU
Heating Capacity Range 8,700~27,000 BTU
Rated Power Input 1,920 W
HSPF 12.0
Operating Range
Cooling 14~115°F (-10~46°C)
Heating -31~75°F (-35~24°C)
CUS
Intertek
18000 BTU/HR WALL MOUNTED INVERTER DRIVEN HEAT PUMP SYSTEM
ASH118URDSD / ASYW18URDWD
Pipe Length
Minimum Pipe Length 6 ft
Maximum Pipe Length 83 ft
Maximum Pipe Height Dierence 50 ft
Flare Connection
1/4”(Discharge)
1/2”(Suction)
Remote Controller
Ships with YR-HQ
Wired Controller
Compatible with wired controller ACT17CWA
Wind Bae
Uses wind bae QAWB45A
Built-in Features
• WK-B wired controller adapter
• WiFi
• Occupancy sensor
Accessories
For more information visit us:
www.geappliances.com/ductless
Connecting cable to indoor units must be 14/4 AWG unshielded
stranded copper. Cable must be ran continuous, without splicing.
Job Name: ____________________________
Purchaser: ____________________________
Submitted To: _________________________
Construction: _________________________
Reference: ____________________________
Approval: _____________________________
Date: ________________________________
Submitted By: ________________________
Unit: ________________________________
Drawing #: ____________________________