GE Endure Series Submittal
ENDURE SERIES SUBMITTAL
Rev. April 2020
Outdoor Unit
Compressor DC inverter Driven Rotary
Uncrated Dimension (HxWxD)
27 1/2 x 35 x 13 7/8 in
(697 x 890 x 353 mm)
Crated (HxWxD)
31 1/2 x 41 1/8 x 18 1/8 in
(800 x 1046 x 460 mm)
Outdoor Sound Rating dB 54
Heat Exchanger Fin Type Blue Fin
Weight (Ship/Net) 115.5/98.3 lbs
Factory Refrigerant Charge R-410A (56.8 oz)
Indoor Unit
Uncrated Dimension (HxWxD)
12 7/8 x 39 3/4 x 8 3/4 in
(327 x 1009 x 223 mm)
Crated (HxWxD)
16 x 42 3/4 x 11 5/8 in
(405 x 1085 x 296 mm)
Airflow CFM
(Turbo/High/Med/Low/Quiet)
583/383/324/264/240
Indoor Sound Level dB
(Turbo/High/Med/Low/Quiet)
45/37/34/31/28
Motor Rating (HP) 0.04
Heat Exchanger Fin Type Blue Fin
Weight (Ship/Net) 35.7/27.8 lbs
9000 BTU/HR WALL MOUNTED INVERTER DRIVEN HEAT PUMP SYSTEM
ASH109URDSD / ASYW09URDWD
1U09/12EH2VHD
35 (890)
27 1/2 (697)
13 7/8 (353)
39 3/4 (1009)
8 3/4 (223)
12 7/8 (327)
AW09EH2VHD
Capacity and power usage are measured under the assumption of indoor humidity of 46%
Heating Capacity Data
Outdoor
Air Temp
DB
Indoor Set Temperature
60
O
F (16
O
C) 70
O
F (21
O
C) 77
O
F (25
O
C)
Maximum Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
-31
O
(-35
O
) 3,050 1,180 3,200 1,300 3,250 1,370
-22
O
(-30
O
) 7,100 1,230 7,400 1,350 7,530 1,410
-15
O
(-26
O
) 8,260 1,380 8,600 1,480 8,750 1,520
-4
O
(-20
O
) 10,100 1,570 10,500 1,660 10,700 1,710
5
O
(-15
O
) 11,500 1,590 12,000 1,670 12,250 1,740
17
O
(-8
O
) 12,900 1,500 13,500 1,550 13,750 1,610
47
O
(8
O
) 15,400 1,480 16,000 1,520 16,300 1,570
Cooling Capacity Data
Outdoor
Air Temp
DB
Indoor Set Temperature
70
O
F (21
O
C) 75
O
F (24
O
C) 80
O
F (27
O
C)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
14
O
(-10
O
) 6,700 610 6,500 540 6,200 480
65
O
(18
O
) 8,000 700 7,740 670 7,380 620
75
O
(24
O
) 9,450 830 9,150 800 8,940 780
85
O
(29
O
) 11,650 950 11,050 910 10,500 860
95
O
(35
O
) 13,000 1,080 12,200 1,000 11,500 960
105
O
(41
O
) 11,700 1,120 11,100 1,060 10,600 1,010
115
O
(46
O
) 10,060 1,050 9,600 990 9,150 930
Capacity and power usage are measured under the assumption of indoor humidity of 46%