GE Endure Series Submittal

ENDURE SERIES SUBMITTAL
Rev. April 2020
Electrical Requirement
Power Supply
208/230V, 1 Phase,
60 HZ
Operating Voltage Range 187~253 VAC
Recommended Fuse/Breaker Size 15A
MCA 13A
Cooling Performance
Rated Cooling Capacity 9,000 BTU
Cooling Capacity Range 3,100~12,000 BTU
Rated Power input 550 W
SEER 30.0
EER 16.0
Moisture Removal 2.5 Pt./h
Heating Performance
Rated Heating Capacity 10,000 BTU
Heating Capacity Range 3,100~20,000 BTU
Rated Power Input 845 W
HSPF 15.2
Pipe Length
Minimum Pipe Length 6 ft
Maximum Pipe Length 50 ft
Maximum Pipe Height Dierence 33 ft
Flare Connection
1/4”(Discharge)
1/2”(Suction)
Operating Range
Cooling 14~115°F (-10~46°C)
Heating -31~75°F (-35~24°C)
Job Name: ____________________________
Purchaser: ____________________________
Submitted To: _________________________
Construction: _________________________
Reference: ____________________________
Approval: _____________________________
Date: ________________________________
Submitted By: ________________________
Unit: ________________________________
Drawing #: ____________________________
CUS
Intertek
Accessories
9000 BTU/HR WALL MOUNTED INVERTER DRIVEN HEAT PUMP SYSTEM
ASH109URDSD / ASYW09URDWD
Remote Controller
Ships with YR-HQ
Wired Controller
Compatible with wired controller ACT17CWA
Wind Bae
Uses wind bae QAWB37A
Built-in Features
WK-B wired controller adapter
WiFi
Occupancy sensor
Connecting cable to indoor units must be 14/4 AWG unshielded
stranded copper. Cable must be ran continuous, without splicing.
For more information visit us:
www.geappliances.com/ductless