MDS 05-3627A01, Rev. D LEDR Series I/O Guide 29
4.7 STEP 6Set TCP/IP Settings to Enable SNMP
and/or Telnet Management (if required)
The unit IP address is factory configured with a unique address
based on the last three digits of the radio’s serial number.
Use
ip command (Page 63) to change the IP address, set net-
mask, gateway and IP Port as necessary.
In a protected radio, change the
rdnt settings (Page 74) to match
the user-assigned IP addresses.
4.8 STEP 7Set User Configurable Fields
Change only
if required.
Many items are user-configurable. These include, but are not lim-
ited to the following. See the NMS command description in the
manual for more detail:
Set user information fields using
info command (Page 62)
Set alarms and alarm mappings using the
alarm command
(Page 50)
Set event mappings using the
evmap command (Page 58)
Set alarm thresholds using the
threshold command (Page 83)
Set the SNMP community using the
snmpcomm command
(Page 81)
4.9 STEP 8Verify Radio Performance
The data performance and NMS should be verified. Use the loop-
back
command (Page 69) to verify data throughput.
4.10 STEP 9Install the Link
Peak the antennas for maximum RSSI using the continuously
updated
rssi command (Page 79), either the front panel screen or
using the
trend command (Page 85) via the NMS.
4.11 STEP 10Verify the Link Performance
Connect and verify the proper operation of external equipment con-
nected to the LEDR radio link.
5.0 CONFIGURATION AND CONTROL
VIA THE FRONT PANEL
Figure 15 shown on the following pages is a pictorial view of the front
panel menu tree. Detailed explanations of the screens are follow in
Section 5.1, Front Panel LCD Menu Descriptions.