User's Manual

Table Of Contents
MDS 05-3627A01, Rev. D LEDR Series I/O Guide 131
NOTE: The event codes listed here are available on radios equipped
with the optional FT1 Interface Board. Standard S Series
radios will display fewer codes.
Table 33. Event Codes
ID EVENT NAME DESCRIPTION DEFAULT
LED
SNMP
TRAP
LEVEL
0 EXT_ALARM_IN1 External Alarm Input #1 ALARM CRITICAL
1 EXT_ALARM_IN2 External Alarm Input #2 ALARM CRITICAL
2 EXT_ALARM_IN3 External Alarm Input #3 ALARM CRITICAL
3 EXT_ALARM_IN4 External Alarm Input #4 ALARM CRITICAL
4 MODULATOR_EV Communication failure
with modulator
ALARM CRITICAL
5 DEMODULATOR_EV Communication failure
with demodulator
ALARM CRITICAL
6 MOD_SELFTEST Modulator selftest failed NONE CRITICAL
7 DEMOD_SELFTEST Demodulator selftest
failed
NONE INFORM
8 PERM_REGN_CHECKSUM Permanent region
checksum failed
NONE INFORM
9 APP1_REGN_CHECKSUM Application #1 checksum
failed
NONE INFORM
10 APP2_REGN_CHECKSUM Application #2 checksum
failed
NONE INFORM
11 BOOT_REGN_CHECKSUM Boot loader checksum
failed
NONE INFORM
12 CONF1_REGN_CHECKSUM Configuration Data region
#1 checksum failed
NONE INFORM
13 CONF2_REGN_CHECKSUM Configuration Data region
#2 checksum failed
NONE INFORM
14 RTC_TEST Real-time clock error NONE INFORM
15 BBRAM_TEST NV-RAM test failed NONE INFORM
16 BATTERY_LOW NV-RAM battery is low ALARM MAJOR
17 TX_SYNTH_LOCK Transmit Synthesizer
out-of-lock
TXALARM CRITICAL
18 RX_SYNTH_LOCK Receive Synthesizer
out-of-lock
RXALARM CRITICAL
19 DIG_POWER_REF Digital Power Reference
is out of specified range
ALARM CRITICAL
20 TEMPERATURE Temperature sensor
reads over 80 degrees
Celsius
ALARM CRITICAL
21 TX_POWER_LOOP Transmit Power Loop is
out-of-lock
TXALARM MAJOR
22 DEMOD_SNR_LOW Demodulator
Signal-to-Noise ratio is
unacceptably low
NONE MINOR