User's Manual

Table Of Contents
124 LEDR Series I/O Guide MDS 05-3627A01, Rev. D
Transmitter
Transmit Power: +30 dBm (1 watt) at antenna port
Output Control Range: 0 dB to 10 dB
Frequency Stability: 1.5 ppm
Spurious Outputs: < 60 dBc 400S
< 60 dBc 900S
< 60 dBm 1400S
Receiver
Sensitivity (for 10
-6
BER): Bandwidth Data Rate Sensitivity
25 kHz 64 kbps 101 dBm
50 kHz 128 kbps 98 dBm
100 kHz 256 kbps 95 dBm
200 kHz 768 kbps 92 dBm
Residual BER: < 1 x 10
-10
Dynamic Range: > 65 dB
Interfaces
Data: EIA-530,
G.703 100 , balanced (RJ-45)
with optional FT1 Interface Board
Orderwire: Voice handset interface, DTMF capable
Service Channel: RS-232 @ 9600 bps
Ethernet: 10 Base-T
Console Port: RS-232, 9600 bps to 115200 bps
Alarms: 4 programmable outputs; 4 inputs
Antenna: 50 Impedance
Network Management System
Accessibility: Via built-in HTTP server or command line interface
SNMP Management (Optional): Using MIB II and custom enterprise MIB
Diagnostic Functions
Via Front Panel LEDs: Power, Active, General Alarm, Rx Alarm, Tx Alarm
& I/O Alarm
Via Front Panel LCD Display : Measurements of
RSSI, RF Power, Signal-to-Noise ratio, BER
Data Loopback: Local and Remote
Agency Approvals
LEDR 400S EMC: ETS 300 385
LEDR 900S Transmission: FCC Part 101, RS-119
EMC: FCC Part 15
LEDR 1400S Transmission: ETS 300 630, MPT 1717