62 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Custom Data Buffer Size (Custom Packet Mode only)—Maxi-
mum amount of characters, that the Remote end will buffer
locally before starting to transmit data through the serial port.
[
16, 32, 64, 128, 256; 32]
Commit Changes and Exit Wizard—Save and execute changes
made on this screen (Shown only after changes have been
entered.)
Invisible place holder
Figure 3-27. UDP Point-to-Point Menu
Use UDP point-to-point configuration to send information to a single
device.
Status—Enable/Disable the serial data port.
IP Protocol—UDP Point-to-Point. This is the type of IP port
that will be offered by the transceiver’s serial device server.
[
TCP, UDP, PPP; TCP]
Remote IP Address—Data received through the serial port is
sent to this IP address. To reach multiple Remotes in the net-
work, use UDP Point-to-Multipoint.
[
Any legal IP address; 0.0.0.0]
Remote IP Port—The destination IP port for data packets
received through the serial port on the transceiver. [
1–64,000;
COM1: 30010, COM2: 30011
]
Local IP Port—Port number where data is received and passed
through to the serial port. This port number must be used by
the application connecting to this transceiver. [
1–64,000;
COM1: 30010, COM2: 30011
]