User's Manual
120 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
* Condition may be corrected by user and alarm cleared.
4.1.5 Correcting Alarm Conditions
(See View Event Log on Page 81)
Table 4-6 provides insight on the causes of events that inhibit the unit
from operating, and possible corrective actions. The Event Description
column appears on the
Event Log screen.
EVENT_REMOTE Remote Added/
Removed (AP only)
eventRemote(66)
EVENT_REPETITIVE The previous event is
occurring repetitively
EVENT_ROUTE_ADD Manual entry added to
Routing table
routeAdded(68)
EVENT_ROUTE_DEL Manual entry deleted
from Routing table
routeDeleted(69)
EVENT_RSSI
*
RSSI Exceeds
threshold
rssi(11)
EVENT_RSSI_CAL RSSI Not Calibrated rssiCal(9)
EVENT_SDB_ERR Internal
Remote/Endpoint
database error (AP
only)
sdbError(80)
EVENT_SINREM_SWITCH Eth/Serial mode switch
in a Single Remote
sinRemSwitch(70)
EVENT_SYSTEM_ERROR* System Error Cleared;
Please Reboot
systemError(16)
EVENT_TFTP_CONN TFTP connectivity
achieved
tftpConnection(73)
EVENT_TFTP_ERR Attempted TFTP
connection failed
tftpConnFailed(79)
Table 4-5. Alarm Conditions (Alphabetical Order) (Continued)
Alarm Condition Reported Event Log Entry SNMP Trap
Table 4-6. Correcting Alarm Conditions—Alphabetical Order
Event Log Entry Generating Condition Clearing Condition
or Action
ADC Failure The ADC always reads the
same value (either high or
low limit)
Contact factory Technical
Services for assistance
AP Ethernet Link Monitor will check state of
Ethernet link and set alarm if
it finds the link down
Ethernet link is re-established
Bridge Down When the Bridge fails to be
initialized
Contact factory Technical
Services for assistance
Flash Test Failed Internal check indicates
corruption of Flash memory
Contact factory Technical
Services for assistance
FPGA Failure Communication lost to the
FPGA
Contact factory Technical
Services for assistance