User's Manual
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 105
Each resulting file should be saved with a different name. We recom-
mend using directories and file names that reflect the location of the unit
to facilitate its identification.
Editing Rules • You may include only parameters you want to change.
• Change only the parameter values.
• Capitalization counts in some field parameters.
(Example: System Mode)
• Comment Fields
a. Edit, or delete anything on each line to the right of the
comment delineator, the semicolon (;).
b. Comments can be of any length, but must be on the same
line as the parameter, or on a new line that begins with a
semicolon character.
c. Comments after parameters in files exported from a trans-
ceiver do not need to be present in your customized files.
3.9.3 Authorization Keys Menu
Figure 3-56. Authorization Key Menu
• Authorization Key—Initiate the entering of an Authorization Key
into the transceiver’s non-volatile memory.
•
Authorized Features—List of authorized features.
In addition to the four configurations fields, is the
MDS NETview
MS access control. NETview MS is designed to help users mon-
itor system performance, configure network elements, detect
faults and correct problems in the convenience of an office set-
ting or at any other point in the network.