User Manual

70 MDS entraNET 900 System Guide (Preliminary) MDS 05-4055A01, Rev. A
Setting to enable MD5 Digest Authentication
Automatic Key Rotation: disabled
Setting to enable Automatic Key Rotation
Approved APs List Enable: disabled
Setting to enable the Approved Access Points List
Watch-Link-Status Flag @ AP: disabled
A flag that controls whether the Remotes care about the AP's Ether-
net Link Status
Network Name Hash Enable: disabled
A flag that controls whether MD5 hashing is applied to the network
name
End of Configuration File
Editing Configuration Files
Once a Remote unit’s operation is fine-tuned, use the Conguration
Scripts Menu on Page 63 to save a copy of the configuration in a PC.
Once the file is saved in the PC it can be used as a source to generate
modified copies adjusted to match other devices. The configuration files
can be modified using a text editor or an automated process. (Not pro-
vide by MDS).
We recommend that you review and update the following parameters for
each individual unit. Other parameters may also be changed.
Table 2-6. Common User-Alterable Parameters
Field Comment Range
IP Address Unique for each individual radio Any legal IP address
IP Gateway May change for different groups or
locations
Any legal IP address
Unit Name Should reflect a specific device.
This information will appear in
entraNET Management System
headings
Any 20-character
alphanumeric string
Location Used only as reference for network
administration
Any 40-character
alphanumeric string
System Mode The application of the parameter in
this field is dependent on the
authorized options stored in the
units permanent memory.
The mode must be compatible with
any previously installed
Authorization Keys.
Access Point
Dual Remote
Serial Remote
Ethernet Remote
NOTE: These are
case-sensitive.
Network Name Used to identify different groups or
locations
Any 15-character
alphanumeric string