38 MDS entraNET 900 System Guide (Preliminary) MDS 05-4055A01, Rev. A
Invisible place holder
Figure 2-17. Point-to-Point Serial-to-Serial Application Diagram
EIA-232
RTU
EIA-232
Terminal
or Computer
192.168.0.10 192.168.0.1 192.168.0.2
iNET 900
Remote
iNET 900
Access Point
L
A
N
C
O
M
1
C
O
M
2
P
W
R
L
I
N
K
Table 2-2. Serial Port Application Configuration
MDS entraNET 900
Unit Location
Menu Item Setting
Access Point (COM2)
1
Status Enabled
Data Baud Rate 9,600 (Example)
Flow Control Hardware (Example)
Seamless Mode Disabled
Delimiter (Chars) 0
Buffer Size 0
IP Protocol UDP
Send to Address 192.168.0.2
(IP address of the entraNET
Remote)
Send to Port 30011
Receive on Port 30011 (Not used)
Receive on
Address
0.0.0.0 (Not used)
Remote Unit (COM2)
1
Status Enabled
Data Baud Rate 9,600 (Example)
Flow Control X-ON/X-OFF (Example)
Seamless Mode Disabled
Delimiter 0 (Characters)
Buffer Size 0 (Characters)
IP Protocol UDP
Send to Address 192.168.0.1
(IP address of the entraNET AP)
Send to Port 30011
Receive on Port 30011 (Not used)
Receive on
Address
0.0.0.0 (Not used)
1. Either COM port can be used, but they must be the same ones at both ends
of the link. Both COM ports can be used simultaneously for two independent
data channels.