User's Manual
Table Of Contents
- 1.0 ABOUT THIS MANUAL
- 2.0 PRODUCT DESCRIPTION
- Multiple Address Systems (MAS)
- Point-to-Point System
- Adding a Tail-End Link to an Existing Network
- Extending a TransNET Network with a Repeater
- 3.0 INSTALLATION PLANNING
- Terrain and Signal Strength
- Conducting a Site Survey
- Antennas
- Feedlines
- Antenna System Ground
- 4.0 INSTALLATION
- 4.1 Transceiver Installation
- a. Set the Mode using the MODE M (Master), MODE R (Remote), or MODE X (Extension) command. (Note: There can be only one Master r...
- b. Set a unique Network Address (1-65000) using ADDR command. Each radio in the system must have the same network address. Tip: Use the last four digits of the Master’s serial number to help avoid conflicts with other users.
- c. Set the baud rate/data interface parameters. Default setting is 9600 bps, 8 data bits, no parity, 1 stop bit. If changes are ...
- 4.2 Configuring Multiple Remote Units
- 4.3 Tail-End Links
- 4.4 Configuring a Network for Extensions
- 4.1 Transceiver Installation
- 5.0 OPERATION
- Antenna Aiming
- Antenna SWR Check
- Data Buffer Setting-Modbus Protocol
- Hoptime Setting
- TotalFlow™ Protocol at 9600 with Sleep Mode
- Operation at 115200 bps
- Baud Rate Setting
- Radio Interference Checks
- 6.0 RADIO PROGRAMMING
- Terminal Interface
- PC-Based Configuration Tool
- Entering Commands
- ADDR [1-65000]
- AMASK [0000 0000-FFFF FFFF]
- AT [ON, OFF]
- ASENSE [HI/LO]
- BAUD [xxxxx abc]
- BAND [A, B, C]
- BUFF [ON, OFF]
- CODE [NONE, 1…255]
- CSADDR [1-65000, NONE]
- CTS [0-255]
- CTSHOLD [0-60000]
- DEVICE [DCE, CTS KEY]
- DLINK [xxxxx/ON/OFF]
- DKEY
- DTYPE [NODE/ROOT]
- FEC [ON, OFF]
- HOPTIME [7, 14, 28]
- INIT
- HREV
- KEY
- LED [ON, OFF]
- LPM [1, 0]
- LPMHOLD [0-1000]
- MODE [M, R, X]
- MRSSI [NONE, -40...-90]
- OT [ON, OFF]
- OWM [xxxxx]
- OWN [xxxxx]
- PORT [RS232, RS485]
- PWR [20-30]
- REPEAT [0-10]
- RETRY [0-10]
- RSSI
- RTU [ON, OFF, 0-80]
- RX [xxxx]
- RXD [0-235] / [ON/OFF]
- RXTOT [NONE, 0-1440]
- SAF [ON, OFF]
- SETUP
- SER
- SHOW CON
- SHOW PWR
- SHOW SYNC
- SKIP [NONE, 1...8]
- SLEEP [ON, OFF]
- SREV
- STAT
- TEMP
- TX [xxxx]
- UNIT [10000-65000]
- XADDR [0-31]
- XMAP [00000000-FFFFFFFF]
- XPRI [0-31]
- XRSSI [NONE, -40...-120]
- ZONE CLEAR
- ZONE DATA
- 7.0 TROUBLESHOOTING
- Checking for Alarms-STAT command
- Major Alarms versus Minor Alarms
- Alarm Code Definitions
- 8.0 RADIO FIRMWARE UPGRADES
- Saving a Web-Site Firmware File Onto Your PC
- 9.0 OPERATING PRINCIPLES AND CONFIGURATION
- Simple Extended SAF Network
- Extended SAF Network
- Retransmission and ARQ Operation
- SAF Configuration Example
- 1. Mode X and M Radios-Can have direct reports (Mode R radios) outside of the chain.
- 2. Data (Payload)-Travels from Master to Remote, and back from Remote to Master.
- 3. Mode X and R Radios-Extension links can be protected by mapping one or more fall-back paths in case of a failure. Add seconda...
- 9.2 Synchronizing Network Units
- Synchronization Messages
- Sleep Mode Example
- Setup Commands
- Reading RSSI and Other Parameters with LPM Enabled
- Power Consumption Influence by HOPTIME and SAF Settings
- Introduction
- Operational Influences-Hoptime & SAF
- Master Station Configuration
- Antenna System for Co-Located Master Stations
- 10.0 TECHNICAL REFERENCE
- 10.1 Product Specifications-900 MHz
- 10.2 Product Specifications-2.4 GHz
- 10.3 Diagnostic Interface Connections (RJ-11)
- 10.4 Data Interface Connections (DB-9F)
- Pin Descriptions-RS/EIA-232 Mode
- Pin Descriptions-RS/EIA-422/485 Mode
- Using the I/O Points with InSite™ NMS Software
- Application Example-Digital Input and Output at a Remote
MDS 05-2708A01, Rev. D MDS TransNET I&O Guide 41
SHOW CON
Show Virtual Connection Status
Shows virtual connection status established by the latest ATDT command
sequence. (Works only with AT ON. See“AT [ON, OFF]” on Page 29)
If no connection is established, it displays NONE.
If a connection is active, it will display:
<Master unit address> TO <Remote (“dialed”) unit address>.
SHOW PWR
Show Measured RF Transmit Power
The SHOW PWR command displays the actual (measured) RF power output
in dBm. Unlike the PWR command, this command shows the actual level
being measured, not the programmed RF power setting.
SHOW SYNC
Show Clock-Synchronization Master Network Address
When used at a Remote station, this command will display Extended Address
and Unit Address of the Master or Extension radio to which the Remote is
synchronized. The network depth at the Remote, defined as the number of
downstream links from the Master, is displayed in parentheses.
SHOW SYNC works for Dependent Masters. A value of zero (0) means the
station is a Master synchronized to a Clock-Sync Master. The SHOW SYNC
command will display an asterisk (*) after depth value if the radio is operating
with co-located Masters.
SKIP [NONE, 1...8]
Skip Radio Operating Zones
This command sets or displays which, if any, of the eight zones will be
skipped from the radio’s hopping sequence. Skipping zones is one way of
dealing with constant interference on one or more frequencies in the radio’s
operating band. See “A Word About Radio Interference” on Page 8 for more
information on dealing with interference.
Tables 13, 14, 15 and 16 show the frequency range covered by each zone. The
command parameter is either the keyword NONE or an undelimited string of
up to four digits where each digit 1...8 represents a corresponding zone to
skip. (For zone parameter input, the digits can appear in any order and can be
optionally separated by a blank space.) The SKIP command is display-only at
Remote radios. (Remotes must be synchronized with the Master radio to
display the skip status.)